![Komatsu PC45MR-30403 Скачать руководство пользователя страница 323](http://html1.mh-extra.com/html/komatsu/pc45mr-30403/pc45mr-30403_operation-and-maintenance-manual_1991268323.webp)
METHOD FOR CHANGING OIL IN HYDRAULIC TANK, CLEANING HYDRAULIC TANK STRAINER... 4-89
METHOD FOR CHECKING AND RELEASING NITROGEN GAS CHARGE PRESSURE IN ACCUMULA-
TOR (FOR CONTROL CIRCUIT) ........................................................................................................ 4-93
METHOD FOR CHECKING ALTERNATOR AND STARTING MOTOR ................................................... 4-97
EVERY 3000 HOURS MAINTENANCE ......................................................................................................... 4-98
METHOD FOR CHECKING AND CLEANING FUEL INJECTION SYSTEM............................................ 4-98
EVERY 4000 HOURS MAINTENANCE ......................................................................................................... 4-99
REPLACE DEFINED LIFE PARTS.......................................................................................................... 4-99
METHOD FOR REPLACING ACCUMULATOR (FOR CONTROL CIRCUIT) ........................................ 4-100
EVERY 6000 HOURS MAINTENANCE ....................................................................................................... 4-101
METHOD FOR CLEANING KDPF ........................................................................................................ 4-101
MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER
For machine equipped with a hydraulic breaker, the hydraulic oil deteriorates faster than for normal bucket dig-
ging operations, so set the maintenance intervals as follows.
Replace hydraulic filter element
On a new machine, replace the element after the first 100 to
150 hours, then perform further replacement of the element ac-
cording to the table.
Change of oil in hydraulic tank
Change the oil according to the table.
X:
Breaker operating ratio ( %)
Y: Replacement interval (H)
(A):Element of hydraulic tank
(B):Hydraulic oil
REMARK
Breaker operating ratio 100 % means that only the breaker is
used.
Breaker operating ratio 0 % means that the breaker is not used.
MAINTENANCE SCHEDULE
MAINTENANCE
4-14
Содержание PC45MR-30403
Страница 61: ......
Страница 62: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 64: ...14 Engine rear cover 15 Cooling cover 16 Battery 17 KDPF OPERATION GENERAL VIEW 3 3...
Страница 310: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 411: ......
Страница 412: ...SPECIFICATIONS 5 1...
Страница 417: ......
Страница 459: ......
Страница 460: ...REPLACEMENT PARTS 7 1...
Страница 475: ...PC45MR 5 PC55MR 5 HYDRAULIC EXCAVATOR Form No TEN00763 04 2018 KOMATSU All Rights Reserved Printed in Japan 02 2018...