7.14
Section 7
Electrical System and Components
8. Take out the drive lever and pull the armature
out of the drive end cap. See Figure 7-24.
9. Remove the thrust washer from the armature
shaft. See Figure 7-24.
11. Remove the retainer from the armature shaft.
Save the stop collar.
NOTE:
Do not reuse the old retainer.
Figure 7-24. Armature and Lever Removed.
10. Push the stop collar down to expose the retaining
ring. See Figure 7-25.
Figure 7-25. Retaining Ring Detail.
Figure 7-26. Removing Retaining Ring.
12. Remove the drive pinion assembly from the
armature.
13. Clean the parts as required.
NOTE
:
Do not
soak the armature or use solvent
when cleaning. Wipe clean using a soft
cloth, or use compressed air.
Figure 7-27. Delco-Remy Starter.
Screw
Plunger
Spring
Lever
Plate
Plug
Solenoid
Frame & Field
Brush Holder
Nut
Commutator
End Plate
Screw
Bolt
Drive
End Cap
Collar
Retaining Ring
Stop
Drive
Armature
Washer
Tube