10.11
Section 10
Reassembly
10
3. Install the M5 hex flange nuts onto the studs,
then torque using the sequence shown in
Figure 10-40 to
5.7 N·m (51 in. lb.)
.
3. Note the mark or tag identifying the hydraulic
lifters as either intake or exhaust and cylinder 1
or cylinder 2. Install the hydraulic lifters into
their appropriate location in the crankcase. Do
not use a magnet. See Figure 10-42.
NOTE
: Hydraulic lifters should always be
installed in the same position as they
were disassembled. The exhaust lifters
are located on the output shaft side of
the engine while the intake lifters are
located on the fan side of the engine. The
cylinder numbers are embossed on the
top of the crankcase and each cylinder
head. See Figure 10-43.
Figure 10-40. Breather Assembly Fastener Torque
Sequence.
4. Lightly oil the lower end of the breather hose and
install into the hole in the breather assembly. The
cover should be situated between the two raised
rings of the hose.
Install Hydraulic Lifters
1. See Servicing Hydraulic Lifters in Section 9 for
lifter preparation (bleed down) procedures.
2. Apply camshaft lubricant (see Section 2) to the
bottom surface of each lifter. See Figure 10-41.
Lubricate the hydraulic lifters and the lifter
bores in the crankcase with engine oil.
Figure 10-41. Applying Camshaft Lubricant to
Bottom of Lifters.
Figure 10-42. Installing Hydraulic Lifters.
Figure 10-43. Match Numbers on Cylinder Barrel
and Head.
1
3
4
2
Match
Numbers