SuperLite
®
27
®
of solutions shown below, along with the necessary
ordering information and mixing instructions.
NOTE: Ensure helmet liner and cushion are
removed prior to sanitizing the oral-nasal mask/
regulator.
1. SaniZide Plus:
P/N: 34805 (spray) or 34810
(gallon)
,
Ready to use; do not dilute.
SAFETEC of America, Inc
1055 E. Delavan Ave.
Buffalo, NY 14215 USA
1-800-456-7077
2. Advance TBE:
P/N: AD160 (spray) or AD1128
(gallon), Infection Control Technology ): Ready to
use.
Infection Control Technology
1751 So. Redwood Rd.
Woodscross, UT 84087 USA
1-800-551-0735
3. Bi-Arrest 2:
P/N: BP201 (4 ounces) or BP 222
(32 ounces), Infection Control Technology. Mix two
pumps of the concentrate with 16 ounces of fresh
water.
Infection Control Technology
1751 So. Redwood Rd.
Woodscross, UT 84087 USA
1-800-551-0735
4. Confidence Plus:
P/N: 10009971 (32 ounces)
Mix one ounce of concentrate with one gallon of
fresh water.
Mine Safety Appliances, 1-800-MSA-2222
Sanitizing Procedure:
Unless otherwise directed, use the following pro-
cedure to disinfect the SL 27
®
oral nasal mask and
regulator:
1) Wet or immerse all components to be sanitized.
Allow components to stay in contact with the solu-
tion for at least 10 minutes.
2) If the solution appears to be drying, apply more
solution to keep it wet for the full 10 minutes.
3) After 10 minutes, thoroughly rinse components
under running potable water.
NOTE: The purpose of this procedure is to sani-
tize the components exposed to each of the divers.
KMDSI recommends sanitizing be performed daily
in between use by different divers, after each use, or
when future use is anticipated within the mission
(job) period. KMDSI defines “A mission is defined
as use of the Kirby Morgan commercial diving mask
or helmet over a seven-day period.”
Germicidal cleansing solutions must be
carefully diluted if required in accordance
with the manufacturer’s recommendation.
If solution is not of the recommended
strength, it will not act as an effective
disinfectant. Failure to thoroughly rinse
germicidal cleansing solution from
diving equipment may result in lung
irritation and/or long-term degradation of
rubber and silicone components of this
equipment.
CAUTION