![Kirby Morgan SuperLite 27 Скачать руководство пользователя страница 122](http://html.mh-extra.com/html/kirby-morgan/superlite-27/superlite-27_operation-and-maintenance-manual_1971913122.webp)
106
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
SuperLite
®
27
®
Nose block
device
Oral/nasal
mask
Helmet shell
Knob,
nose block
Packing
nut
Port
retainer
O-ring
8.3 Nose Block Assembly
8.3.1 Nose Block Assembly Removal
Tools Required:
Slip Joint Pliers and a Rag or cloth
7/16 ” Open-End Wrench
1) Hold the nose block knob with a pair of pliers
padded by a cloth, while unscrewing the nose block
device with your hand.
2) After the knob is removed, loosen and remove the
packing nut.
3) Slip the two o-rings off the end of the shaft of the
nose block device and slide the nose block device
out through the oral nasal mask.
4) The padded end of the shaft may be bent with pli-
ers to better fit an individual. A larger pad of rubber
can also be glued onto this pad.
8.3.2 Nose Block Device Replacement
1) Prior to reassembly, lubricate the two O-rings.
2) Slide the shaft through oral nasal mask in the hel-
met shell.
3) Place both O-rings on the shaft, followed by the
packing nut and the knob.
4) Tighten the packing nut until snug. Do not over
tighten, as this will make it difficult to slide the nose
block device in and out.
5) Tighten the knob with the pliers, padded by a
cloth, while holding the pad end with your hand.
Blowapart drawing of
the nose block device and
supporting hardware.
Do not breathe the
fumes from uncured
neoprene cement.
These fumes are
dangerous and can
cause unconscious-
ness. They can also
cause long term
damage to body
tissue. Read and
WARNING
follow all precautions listed on the neo-
prene cement can. Allow neoprene ce-
ment to cure for a minimum of 24 hours
before using helmet.
Install the nose
block device
through the interior
of the oral nasal
mask.