93
SuperLite
®
27
®
WARNING
The oral nasal valve must be replaced
correctly to provide gas flow in the prop-
er direction. The flow through the valve
must be from the interior of the helmet
into the oral nasal mask. This will allow
the diver to breathe the gas from the
defogger valve freely, yet help to reduce
carbon dioxide inside the helmet.
If the valve is not replaced properly this
could make it difficult to breathe the gas
supplied by the defogger and expose
the diver to an excess of carbon dioxide.
This could lead to exhaustion and black-
out resulting in serious injury or death.
7.9.3 Oral Nasal Replacement
1) Snap the oral nasal over the regulator mount nut.
2) Reinstall the microphone.
Exploded view of the Tri-Valve
®
exhaust system.
To remove the Tri-Valve
®
exhaust from the helmet you
must first cut the tie-wrap that secures the exhaust
main body to the regulator.
3) Reinstall the nose block device. See Chapter 8 for
complete instructions on reinstalling the nose block
device.
7.10 Tri-Valve
®
Exhaust Assembly
The Tri-Valve
®
exhaust became standard on the
SuperLite
®
27
®
helmet as of 2005. This is a superior
exhaust system that provides very low exhalation
resistance with an extremely dry breathing system.
Water purge
deflector
Water dump
body
Water
dump valve
Whisker wing
Whisker exhaust
valve insert
Exhaust
valve
Exhaust valve
Helmet
shell
Flange
Exhaust valve
Regulator
body
Exhaust
main body
Valve body,
purge