![Kirby Morgan SuperLite 27 Скачать руководство пользователя страница 154](http://html.mh-extra.com/html/kirby-morgan/superlite-27/superlite-27_operation-and-maintenance-manual_1971913154.webp)
138
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
SuperLite
®
27
®
9.3 Low Pressure Inflator Hose
The low pressure inflator system may be used with
either a buoyancy compensator or dry suit systems.
For certain pieces of equipment it may be necessary
to use a longer inflator hose than is originally sup-
plied by the manufacturer of the low pressure system.
9.3.1 Installation of the Low Pressure
Inflator Hose
Tools Required:
5/32 inch allen wrench attachment on torque wrench
1) Remove the plug from the side block.
Save this
plug.
2) Check the O-ring on the low pressure whip to be
sure it is present and in good condition. Carefully
screw the low pressure whip into the side block.
3) Tighten fitting to the specifications provided by
the dry suit manufacturer. Do not overtighten.
4) Pressurize helmet and test connection for leaks.
Removing the plug from the side block.
When using the low-pressure port on
the side block for attachment of a low-
pressure hose, a hose with built in flow
restriction or the KMDSI Flow Restric-
tor Adapter, P/N 555-210 must be used.
Without a restrictor, a hose failure could
deplete the Emergency Gas Supply very
rapidly leading to suffocation. This could
result in serious personal injury or death.
WARNING
Tighten the fitting on the side block