SuperLite
®
27
®
Never dive if the one way valve is not op-
erating properly. If the hose or breathing
gas/air fitting breaks near the surface a
serious injury could result to the diver’s
lungs and/or eyes. In extreme cases this
could be fatal. The one way valve must be
tested daily prior to the commencement
of diving operations. Failure of the one
way valve could cause serious injury or
death.
WARNING
3.7 Emergency Gas System (EGS)
If the diver’s main gas supply fails, the diver must
have another source of gas that will enable a safe
return to the dive station or to a point where a normal
gas supply can be reestablished. For this reason, an
emergency gas supply (bailout) cylinder must be
used on all dives. The bailout cylinder is normally
worn on the back using a combination backpack and
lifting harness.
Checking the one way valve.
3.6 Preparing the Helmet for Diving
3.6.1 Clean Face Port
Thoroughly clean the face port with a soft cloth and
a mild liquid soap solution. DO NOT USE ANY
AEROSOL SPRAYS ON THE POLYCARBONATE
PORT!
3.6.2 Check Moving Parts
Check all moving parts, such as the regulator adjust
-
ment knob, the defogger control knob, emergency
knob, and the nose block device knob and all locking
collar parts to ensure smooth and proper operation.
3.6.3 Check Communications
Check the communications system for proper opera
-
tion. Put the helmet on and talk to an assistant on the
amplifier. If you are by yourself, with the helmet off
take the helmet near the amplifier and tap on each
earphone and the microphone, listening to the taps
on the amplifier/speaker. Talk into the amplifier/
speaker feeling the vibration on each earphone and
the microphone with your fingertips. Check the fit
and tightness of the comm module mount nut.
3.6.4 One Way Valve Check
T
he one way valve must be tested daily, prior to
commencement of diving operations.
1) Prior to attaching (or pressuring up) the umbilical,
close the emergency valve knob, shut off the defog
-
ger control knob and screw in the adjustment knob
on the regulator all the way. Attach and pressure up
the emergency hose.
2) With the emergency hose pressurized, turn on the
emergency valve knob. If any gas escapes out the end
of the adapter, the one way valve is faulty and must
be rebuilt or replaced. A one way valve repair kit is
available for rebuilding these valves (Part # 525-330).
Never use any aerosol
propelled sprays near
the face port of your
Kirby Morgan helmet.
The propellant used
in these aerosols can
invisibly damage the
WARNING
polycarbonate face port and cause it to
shatter upon impact from any strong blow.
If the face port fails underwater the helmet
will flood and drowning may result.