![Kirby Morgan SuperLite 27 Скачать руководство пользователя страница 164](http://html.mh-extra.com/html/kirby-morgan/superlite-27/superlite-27_operation-and-maintenance-manual_1971913164.webp)
148
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
SuperLite
®
27
®
Supply Pressure
RMV
Depth
ATA
Required
SLPM
w/20% safety
margin
Required
SCFM
FSW
MSW
50
124
38
4.76
237.88
285.45
10.08
62.5
100
31
4.03
251.89
302.27
10.68
75
76
23
3.30
247.73
297.27
10.50
170 PSIG / 11.73 BAR
40
167
51
6.06
242.42
290.91
10.28
50
135
41
5.09
254.55
305.45
10.79
62.5
107
33
4.24
265.15
318.18
11.24
75
86
26
3.61
270.45
324.55
11.46
180 PSIG / 12.42 BAR
40
181
55
6.48
259.39
311.27
11.00
50
148
45
5.48
274.24
329.09
11.62
62.5
115
35
4.48
280.30
336.36
11.88
75
93
28
3.82
286.36
343.64
12.14
190 PSIG / 13.11 BAR
40
190
58
6.76
270.30
324.36
11.46
50
154
47
5.67
283.33
340.00
12.01
62.5
122
37
4.70
293.56
352.27
12.44
75
100
31
4.03
302.27
362.73
12.81
200 PSIG / 13.8 BAR
40
192
59
6.82
272.73
327.27
11.56
50
166
51
6.03
301.52
361.82
12.78
62.5
132
40
5.00
312.50
375.00
13.25
75
102
31
4.09
306.82
368.18
13.01
210 PSIG / 14.49 BAR
40
212
65
7.42
296.97
356.36
12.59
50
175
53
6.30
315.15
378.18
13.36
62.5
137
42
5.15
321.97
386.36
13.65
75
108
33
4.27
320.45
384.55
13.58
220 PSIG / 15.18 BAR
40
220
67
7.67
306.67
368.00
13.00
50
182
56
6.52
325.76
390.91
13.81
62.5
147
45
5.45
340.91
409.09
14.45
75
111
34
4.36
327.27
392.73
13.87
Appendix 3 Table 3 SuperFlow
®
450 SS Balanced Regulator
Low Pressure Compressor Table
Supply Pressure Requirements
Supply Pressure
RMV
Depth
ATA
Required
SLPM
w/20% safety
margin
Required SCFM
FSW
MSW
90 PSIG / 6.21 BAR
40
90
27
3.73
149.09
178.91
6.32
50
76
23
3.30
165.15
198.18
7.00
62.5
62
19
2.88
179.92
215.91
7.63
75
44
13
2.33
175.00
210.00
7.42
100 PSIG / 6.9 BAR
40
101
31
4.06
162.42
194.91
6.88
50
86
26
3.61
180.30
216.36
7.64
62.5
67
20
3.03
189.39
227.27
8.03
Appendix 3 Table 2 Compressor Supply Table SuperFlow
®
and SuperFlow
®
350
Continued