![Kirby Morgan SuperLite 27 Скачать руководство пользователя страница 108](http://html.mh-extra.com/html/kirby-morgan/superlite-27/superlite-27_operation-and-maintenance-manual_1971913108.webp)
92
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
SuperLite
®
27
®
Oral/Nasal
Mask
Regulator
Mount Nut
O-ring
Equalizing
Device
Valve
Body
Oral/Nasal
Valve
The oral nasal mask and the parts associated with
it are easy to access.
The nose block device MUST be removed and
reinstalled when installing a new oral nasal
mask. Simply stretching the oral nasal mask
over the nose block device can cause the oral
nasal mask to tear.
CAUTION
4) Remove the old valve by pulling it out.
5) Install the new valve by feeding the thin tail
through the valve body and pulling on it until the
valve is seated.
6) Install the valve body in the oral nasal. The valve
MUST be on the inside of the oral nasal.
Correct installation of the oral nasal valve is extremely important to your safety.
Correct
WRONG