150
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
SuperLite
®
27
®
Supply Pressure
RMV
Depth
ATA
Required
SLPM
w/20% safety
margin
Required SCFM
FSW
MSW
62.5
153
46
5.64
352.27
422.73
14.93
75
126
38
4.82
361.36
433.64
15.32
200 PSIG / 13.80 BAR
40
222
67
7.73
309.09
370.91
13.10
50
191
58
6.79
339.39
407.27
14.39
62.5
165
50
6.00
375.00
450.00
15.90
75
133
40
5.03
377.27
452.73
15.99
210 PSIG / 14.49 BAR
40
1.00
40.00
48.00
1.70
50
191
58
6.79
339.39
407.27
14.39
62.5
166
50
6.03
376.89
452.27
15.98
75
140
42
5.24
393.18
471.82
16.67
220 PSIG / 15.18 BAR
40
1.00
40.00
48.00
1.70
50
202
61
7.12
356.06
427.27
15.09
62.5
170
51
6.15
384.47
461.36
16.30
75
148
45
5.48
411.36
493.64
17.44
Appendix 3 Table 4 SuperFlow
®
/ SuperFlow
®
350 Regulator
High Pressure Regulated Source
Depth
Regulator Setting
Surface Gauge in P.S.I.G.
Regulator Setting
Surface Gauge in BAR
FSW
MSW
Minimum
P.S.I.G.
Maximum
P.S.I.G.
Minimum
Bar
Maximum
Bar
0-60
0-18
150
225
10.3
15.5
61-100
19-30
200
250
13.8
17.2
101-132
31-40
250
275
17.2
18.9
133-165
41-50
250
300
17.2
19.6
*166-220
51-67
300
325
20.6
22.4
*May not be capable of performing at 75 RMV deeper than 165 FSW.
Performance is based on a minimum of 75 RMV to 165 FSW (50 MSW) and 62.5 RMV to 220
FSW (67 MSW) using a 3/8” (9.5 mm) umbilical 600 foot (183 meters) long, made up of two 300
foot (91 meter) sections.
Appendix 3 Table 3 SuperFlow
®
450 SS Balanced Regulator
Continued