![Kirby Morgan SuperLite 27 Скачать руководство пользователя страница 106](http://html.mh-extra.com/html/kirby-morgan/superlite-27/superlite-27_operation-and-maintenance-manual_1971913106.webp)
90
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
SuperLite
®
27
®
the nut. Note: if there is little (less than 1/16 inch /1.5
mm) or no lever play, the regulator will free flow. If
there is too much free play, (more than 1/8 inch / 3.0
mm) the regulator will not be capable of full demand
flow potential.
7) If the free flow did not stop after this procedure, re
-
fer to regulator disassembly and cleaning procedures.
Alternate method:
If a KMDSI tool kit is not avail
-
able, a small jeweler’s screwdriver or metal scribe can
be inserted in the slot on the end of the inlet valve
(111) to keep it from rotating, and needle nose pliers
may be used to rotate the lever nut. Holding the slot
of the inlet valve from rotating, carefully rotate the
nut “In” (clockwise to remove lever play and “Out”
(counterclockwise) to increase lever play.
Only turn the adjustment nut 1/8 turn at a time. De
-
press the lever momentarily after each adjustment
and observe the lever play. It may be necessary to
complete this procedure several times, as the proce
-
dure requires estimating the proper position of the
nut. If the regulator free flow did not stop after this
procedure, refer to regulator disassembly and cleaning
sections of this manual.
8) When adjustment is complete, place the diaphragm
and cover in place, and press tightly down on the cover
to simulate the action of the clamp.
9) With the cover pressed tight against the diaphragm,
if the regulator starts to free flow, the lever may need
to be bent down slightly. If the regulator does not free
flow, slowly depress the purge button until a slight
free flow develops. The purge button should depress
no further than 1/8 inch (3.0 mm) before the regulator
Press the cover over the diaphragm.
The nut must not be loosened more than
1/8 turn to lower the height of the lever. If
more adjustment is necessary the lever
should be bent downward. If the nut is
loosened more than 1/8 turn the lever
will not have enough travel for proper
flow rates.
CAUTION
The lock nut must always be replaced if
removed from the inlet valve. The plastic
material that locks the nut is not designed
for multiple reuse. If the nut comes loose
during a dive the regulator would free flow
heavily. In the situation where the diver
is using bottled breathing gas this would
result in a rapid consumption of breath-
ing gas.
WARNING
develops a flow. If the regulator does not develop a
slight free flow when the purge button is depressed in
1/8 inch (3.0 mm), then the lever will require slight up
-
ward bending. Note: Before bending the lever, double
check the adjustments. It is rare that the lever requires
bending in a regulator that has been in service. Usu
-
ally levers only require bending in new installations
or because of damage during disassembly.
10) Install the clamp and clamp screw. Tighten the
screw to the correct torque (see appendix for torque
specifications).
11) Again, press on the purge button in the cover. It
must have between 1/16 inch (1.5 mm) minimum
and 1/8 (3mm) travel. Otherwise, the lever must be
bent upward (see section in this chapter). If the but
-
ton has only slight or no free travel, the lever must
be bent down.
12) If the lever and purge button travel is correct, the
adjustment is complete.