4-22 Operation Method
RC04-PCR-LA
• AC Voltage Change Characteristics
Changing the frequency or AC voltage linearly over the set
time is called “ramp.” When ramp is speci
fi
ed, frequency or
AC voltage changes from the value set in an address one
before to the set value at the Ramp-speci
fi
ed address, taking
the time speci
fi
ed for ramp. Ramp speci
fi
cation causes “R” to
appear in the F2 or F4 display area.
Changing the frequency or AC voltage in a stepwise manner
is referred to as “step.” In this case, the frequency or AC volt-
age changes in a stepwise manner from the value stored in an
address previous to the address speci
fi
ed for step to the set
value in the step-speci
fi
ed address. When step is speci
fi
ed,
“S” appears in the F2 or F4 display area.
Fig.4-9
Ramp Speci
fi
cation and Step Speci
fi
cation
• Address 0 does not allow ramp speci
fi
cation.
• Ramp speci
fi
ed at the start address is ignored during
execution, and frequency or AC voltage changes by
steps.
• Ramp operation is not available in DC mode.
DESCRIPTION
(For ramp
speci
fi
cation)
(For no ramp
speci
fi
cation)
Ramp (rise)
Ramp (drop)
Step (rise)
Step (drop)