4-34 Operation Method
RC04-PCR-LA
4.3.7 Harmonic Current Analysis Function
Use of the Remote Controller allows output current harmonic analy-
sis. Because the measurement method employed is simpli
fi
ed, it does
not conform to IEC or other standards. To conduct standard-compli-
ant measurements, use our HA01F-PCR-L Harmonics Analyzer.
Harmonic Current Analysis Function Operating Procedure
• The harmonic current analysis function is available only in the AC
or AC-S mode.
1. Press the ESC key to call the home position.
2. Press the CUR HMNC (SHIFT, SIM).
The PCR-LA power supply will enter the key-lock mode automat-
ically.
3. Press the F1 (ALL/ODD/EVEN) key to select “ALL” (all har-
monics), “ODD” (odd number harmonics), or “EVEN” (even
number harmonics).
Selection changes in the following order whenever the F1 key is
pressed.
4.
Press the F3 (%) key or F5 (Arms) key to select “%” or “Arms”.
When the F3 (%) key is pressed, the harmonic current value is dis-
played as a percentage, with a current value not containing har-
monic current regarded as 100%.
C u r r e n t
H a r m o n i c
A L L
%
A r m s
F1
F2
F3
F4
F5
ALL
ODD
EVEN
(First display
for ALL)
1 :
%
2 :
%
3 :
%
4 :
%
(First display
for ODD)
1 :
%
3 :
%
5 :
%
7 :
%
(First display
for EVEN)
1 :
%
2 :
%
4 :
%
6 :
%