4-24 Operation Method
RC04-PCR-LA
6. Then, press the MENU key to display the third and forth dis-
plays, and set each item of these in the same way as in step 3.
7. Press the ESC key to exit the sequence setting mode.
This will cancel the key-lock mode in the PCR-LA power supply.
Pressing the ESC key on the PCR-LA power supply also allows
you to exit the sequence setting mode in the same way.
• Address 0 allows no ramp speci
fi
cation. Ramp speci
fi
ed for the
start address is ignored, and frequency or AC voltage changes in
step form.
• Starting sequence operation in the DC mode causes frequency and
AC voltage setting to be ignored.
(Third display)
When the F3 key is pressed, the display shown
below appears.
When the ESC key is pressed, the display
below returns to the third display.
1
0 . 0 m
Ω
+ 0 . 0 V
A D R S
I M P
V d c
F1
F2
F3
F4
F5
I M P
4 5 %
4 5 0 m
Ω
(Fourth display)
Each time the F3, F4, or F5 key is pressed, ON
and OFF change alternately.
1
O N
O F F
O N
A D R S
S T A T
T R G O U T
F1
F2
F3
F4
F5