RC04-PCR-LA
Operation Method 4-25
• Note that when voltage data is read from memory in the AC +
DC mode for output, the output voltage changes as shown
below:
An AC voltage set value (Vac) and DC voltage set value
(Vdc) are stored independently in the memory. When they are
read, AC voltage (Vac) is output slightly faster (approxi-
mately 30
μ
s) than DC voltage (Vdc). Therefore, output volt-
age changes as follows:
Example
ADRS1:
Vrms = 0 V, Vdc = +100 V
ADRS2:
Vrms = 100 V, Vdc = 0 V
ADRS3:
Vrms = 0 V, Vdc = +100 V
Fig.4-10
Changes in the Output Voltage in Reading
Data from Memory
In the actual waveform, since the 30
μ
s shown in the above
fi
gure is very short in comparison with each ADRS time, out-
put voltage changes like pulse.
NOTE
30
μ
s
30
μ
s
ADRS3
ADRS2
ADRS1
(100 V)-
(241 V)-
0 V-
Vrms (ADRS1)
+ Vdc (ADRS1)
Vrms (ADRS3)
+ Vdc (ADRS3)
Vrms (ADRS2)
+ Vdc (ADRS2)
Vrms (ADRS3) + Vdc (ADRS2)
Vrms (ADRS2) + Vdc (ADRS1)
Содержание RC04-PCR-LA
Страница 1: ...RC04 PCR LA Part No Z1 002 902 IA002963 Jan 2007 OPERATION MANUAL REMOTE CONTROLLER PCR LA Series...
Страница 10: ...1 4 General RC04 PCR LA...
Страница 78: ...7 4 Specifications RC04 PCR LA 7 2 Dimensions Fig 7 1 Dimension of RC04 PCR LA 40 MAX 55 128 180 Unit mm...
Страница 100: ...A 22 Appendix RC04 PCR LA...