4-32 Operation Method
RC04-PCR-LA
The following are examples of sequence operations and their
sequence set values.
1. Output frequency/voltage
sweep
This example shows that a voltage
of 50 V at 20 Hz was output for
0.2 sec, both voltage and fre-
quency were ramp changed to 100
V and 60 Hz over 0.3 sec, and
then an output of 100 V at 60 Hz
was held for 0.2 sec.
2. Automatic power line environment test
In this example, voltage was
fi
rst changed from 0 V (for 0.2
sec) to 100 V, 132 V, and then to
85 V at 0.1 second intervals,
instantaneously dropped to 30 V
for 0.05 second, and recovered
to 132 V. Then, 0.05 second
later, the voltage was ramp
changed to 0 V over 0.15 second
and held at 0 V for 0.1 second.
Finally, the voltage was ramp changed to 85 V over 0.15 second and
held at 85 V for 0.2 second.
3. AC + DC Output
In this example, 16 Hz, 50 VAC
voltage was superimposed on +48
VDC voltage and output for one
second. Then 16 Hz, 50 VAC volt-
age was superimposed on -48
VDC voltage and output for one second.
The set values of these sequence operation examples are given in the
setting sheet on the next page. The setting sheet is included in the
Fig.4-14
Fig.4-15
Fig.4-16