4-36 Operation Method
RC04-PCR-LA
4.3.8 Special Waveform Output
Use of the Remote Controller allows the PCR-LA power supply to
output not only a sine wave, but also a “peak-clipped waveform” in
which the peak of a sine wave is suppressed. This function can be
used not only for a variety of electronics devices but also for chemical
experiments and production facilities.
To use this feature, set the waveform in the waveform banks in the
special waveform setting mode, and read the waveform in the special
waveform output mode for output.
Fig.4-17
Peak-clipped Waveform
• Only sine waves and peak-clipped waveforms can be set using this
device. However, user-de
fi
ned waveforms created via the Remote
Interface can also be read.
• Waveform Bank
The Remote Controller stores output voltage waveform data in
the internal memory and generates the reference waveform for
output voltage by D/A conversion of such data. An area of the
memory for one waveform of such waveform data is called a
waveform bank. A waveform banks for 15 waveforms are pro-
vided; these are numbered W00 to W14. A waveform is
selected using such a number. Waveform bank W00 stores the
sine wave, which is the reference voltage waveform of the
PCR-LA AC power supply. The W00 content cannot be re-
stored. In the Initial Setup Status, the same waveform as that of
W00 (that is, a sine wave) is stored in all the waveform banks.
Waveform bank display
SIN: Sine waveform
P.C: Peak-clipped waveform
USR: User de
fi
ned waveform (see the PCR-LA AC Power
Supply Operation Manual.)
• Crest Factor
Crest factor is the ratio between AC waveform rms and peak
values.
DESCRIPTION
Содержание RC04-PCR-LA
Страница 1: ...RC04 PCR LA Part No Z1 002 902 IA002963 Jan 2007 OPERATION MANUAL REMOTE CONTROLLER PCR LA Series...
Страница 10: ...1 4 General RC04 PCR LA...
Страница 78: ...7 4 Specifications RC04 PCR LA 7 2 Dimensions Fig 7 1 Dimension of RC04 PCR LA 40 MAX 55 128 180 Unit mm...
Страница 100: ...A 22 Appendix RC04 PCR LA...