background image

RC04-PCR-LA

Index  I-1

A

AC + DC mode  - - - - - - - - - - - - 4-4
AC + DC voltage peak value - - - 4-5
AC voltage change characteristics   4-

22

B

Back-up  - - - - - - - - - - - - - - - - - 3-4

C

Changes in the output voltage in read-

ing data from memory - - 4-8, 4-25

Contrast adjustment  - - - - - - - - - 3-2
Crest factor - - - - - - - - - - - - - -  4-36
Current display mode change   - - 4-4

D

Display should change to the Initial 

Setup Status   - - - - - - - - - - - - 3-4

E

ENTER wait - - - - - - - - - - - - - - 3-2
Example of sequence operation   4-31

F

Frequency setting function   - - - - 4-3

H

Harmonic current analysis   - - -  4-34
Harmonic current analysis operating 

A-12

Home position   - - - - - - - - - - - - 3-2

I

Initial setup status  - - - - - - - - - - 3-1

L

Limit value setting function   - - - 4-4

M

Memory function - - - - - - - - - - - 4-6
Memory operating  - - - - - - - - - -A-3

O

Operation check   - - - - - - - - - - - 3-3
Output impedance setting  - - - -  4-40
Output ON/OFF phase setting  -  4-42

P

Peak clear - - - - - - - - - - - - - - -  4-11
Peak holding value measurement 4-11
Peak initializing signal  - - - - - -  4-12
Peak value measurement - - - - -  4-10
Peak-clipped waveform   - - - - -  4-36
POL   - - - - - - - - - - - - - - - - - -  4-18
Power line abnormality simulation and 

other operating - - - - - - - - - - -A-5

Power line abnormality simulation op-

eration setting sheet   - - - - - - A-20

R

ramp   - - - - - - - - - - - - - - - - - -  4-22
Regulation adjustment   - - - - - -  4-44
Reset  - - - - - - - - - - - - - - - - - - - 3-2
ROM version   - - - - - - - - - - - - - 3-3

S

Sequence execution mode  - - - -  4-28
Sequence operating   - - - - - - - - -A-8
Sequence operation   - - - - - - - -  4-19
Sequence operation setting sheet A-21
Sequence setting mode  - - - - - -  4-23
Special function operating - - - - A-19
Special waveform output   - - - -  4-36
Special waveform output operating A-

18

Special waveform setting   - - - - A-15
Status signal  - - - - - - - - - - - - -  4-26

Index

Содержание RC04-PCR-LA

Страница 1: ...RC04 PCR LA Part No Z1 002 902 IA002963 Jan 2007 OPERATION MANUAL REMOTE CONTROLLER PCR LA Series...

Страница 2: ...gets lost or soiled a new copy can be provided for a fee In either case please contact Kikusui distributor agent and provide the Kikusui Part No given on cover This manual has been prepared with the...

Страница 3: ...only after you make sure that no voltage is output here Indicates an imminently hazardous situation which if ignored will result in death or serious injury Indicates a potentially hazardous situation...

Страница 4: ...cted prior to opera tion of the Remote Controller Chapter 4 Operation Method Describes the operations of the Remote Controller and the extended functions of the PCR LA AC power supply Chapter 5 Parts...

Страница 5: ...2 9 Quick Reference Card 2 6 Chapter 3 Operation Check 3 1 3 1 Checking the Initial Setup Status 3 1 3 2 Operation Check 3 3 Chapter 4 Operation Method 4 1 4 1 Basic Operation of the Remote Controlle...

Страница 6: ...4 3 12 Zero Calibration Function for Measured Current Values 4 46 Chapter 5 Parts Names and Functions 5 1 Chapter 6 Maintenance 6 1 6 1 Cleaning 6 1 6 2 Before Requesting a Repair 6 2 Chapter 7 Specif...

Страница 7: ...or fast voltage swell pop The function is used to test switching power supplies or electronics devices Sequence operation Sequence operation permits automatic operation by combining output voltage and...

Страница 8: ...t func tions Connecting the Remote Controller to a PCR LA power supply allows additional measurements of the power factor VA and peak holding current to be performed The peak holding current measureme...

Страница 9: ...lation adjustment is performed the PCR LA AC power supply s voltage stability accuracy distortion factor and response speed decrease below the normal capability Therefore this function may not be suit...

Страница 10: ...1 4 General RC04 PCR LA...

Страница 11: ...ensure its normal operation Check the Remote Controller upon receipt for damage that might have occurred during transportation Also check that all items listed below have been provided If the device a...

Страница 12: ...which attaches to the back of the remote con troller never place the remote controller near magnetic susceptible items such as floppy disks and credit cards 2 3 Combination with Other Options The PCR...

Страница 13: ...on cover to one of the two connectors see Fig 2 2 in the remote controller Exercise care that the orientation of the connector is correct 2 Insert the protection cover cover the connector and turn the...

Страница 14: ...onnector which is not used Installation 1 As shown in Fig 2 4 insert the accompanying connector cover from the lower part of the connector 2 Insert the cover till it is locked Fig 2 4 Connector Cover...

Страница 15: ...ment Vibration during movement may cause the remote controller to fall When moving the equipment follow the instructions given in the PCR LA AC Power Supply Operation Manual 2 8 How to Use the Magnet...

Страница 16: ...LA 2 9 Quick Reference Card The remote controller has a quick reference card that briefly describes keys and simulation waveforms This card is useful when using the memory sequence or special wavefor...

Страница 17: ...erations of the AC power supply 3 1 Checking the Initial Setup Status The condition in which a PCR LA AC power supply and this device are simultaneously purchased and power is fed for the first time f...

Страница 18: ...s of OUT PUT ON OFF To return to the Home Position from another mode press the ESC key ENTER Wait This is the condition in which the ENTER key has not yet been pressed to initiate the operations perfo...

Страница 19: ...y connected while the lower part displays the model and ROM version of the Remote controller Regarding the appearance of any display other than the display above see the Note on the next page After a...

Страница 20: ...PCR LA and Three phase Driver 3P03 PCR LA or the Single phase Three phase Output Terminal Kit OT01 PCR6000LA 3 OT01 PCR12000LA 3 or OT01 PCR18000LA 3 If the following display or other messages appear...

Страница 21: ...or MODE Note that these keys are accepted only in the Home Position For information on how to use JOG and SHUTTLE see 3 1 2 How to Use JOG and SHUTTLE in the PCR LA AC Power Supply Operation Manual 2...

Страница 22: ...ol panel The functions are separated into those that can be accomplished in the same way as on the PCR LA AC power supply and those requiring different key operation 4 2 1 FunctionsWhose Key Operation...

Страница 23: ...ak holding current Vmin minimum voltage WATT power Iave average current For an explanation of set values rms peak values and average val ues see the Description Voltage Display Mode in 8 7 Voltage Dis...

Страница 24: ...ote Controller press the Vrms Vpk Vset Vave SHIFT F5 key On the PCR LA AC power supply press the SHIFT V keys Current display mode change To switch the current display mode on the Remote Controller pr...

Страница 25: ...eak Value In the AC DC mode the voltage and frequency limit values respectively set in the AC or DC modes are valid The AC DC mode does not allow current limit change Output Voltage Setting Procedure...

Страница 26: ...C and DC voltages stored in the same memory address For memory addresses 1 to 9 setting is common to both the PCR LA AC power supply and the Remote Con troller The procedure to store data in the memor...

Страница 27: ...call the following display then set waveform bank F3 or DC voltage F5 For the waveform banks see 4 3 8 Special Waveform Output 6 Press the ESC key to quit the memory edit mode Display Key Setting ite...

Страница 28: ...30 s than the DC voltage value Vdc Therefore output voltage changes as follows Example ADRS 1 Vrms 0V Vdc 100V ADRS 2 Vrms 100V Vdc 0V ADRS 3 Vrms 0V Vdc 100V Fig 4 2 Changes in the Output Voltage in...

Страница 29: ...ormation see Table 4 3 To display waveform bank and DC voltage set in the same address press the MENU key 4 To confirm the read set values press the ENTER key To cancel them press the ESC key Pressing...

Страница 30: ...nt Mode The PCR LA AC power supplies have the peak current display func tion However using the Remote Controller allows peak holding cur rent display in addition to peak current display The difference...

Страница 31: ...ed in the AC DC or AC DC mode Peak Clear Procedure The following three methods can be used to clear a peak in the peak holding current measurement Press the F4 clr key on the Remote Controller Short c...

Страница 32: ...mpedance resistance of the circuit to be shorted should be to 50 ohms or less The BNC connector is isolated from the INPUT and OUT PUT terminal boards in the PCR LA AC power supply How ever since the...

Страница 33: ...cial Waveform Output performing power line abnormality simulation causes the waveform to be output as a sine waveform Operation of power line abnormality simulation consists of the parameter setting a...

Страница 34: ...s voltage change to the beginning of the next voltage change the voltage is maintained for Variation Voltage during the interval Specifying zero 0 for this T3 disables this function Second display T4...

Страница 35: ...etting mode display third display When T5 is set to other than integral multiple of 1 cycle the real restoration duration gets longer than the set T5 time because the voltage change is started after t...

Страница 36: ...key to move the cursor to the desired item 6 Set a value using the numeric keys or JOG SHUTTLE For setting using the numeric keys press the ENTER key to con firm the value Select the desired magnific...

Страница 37: ...display is switched in the order of the first to third and the execution mode display whenever the MENU key is pressed To return to the previous display press the SHIFT MENU keys 10 Press the MENU key...

Страница 38: ...bnormality simu lation function This will cancel the key lock mode in the PCR LA power supply Pressing the ESC key on the PCR LA power supply also allows you to exit the power line abnormality simulat...

Страница 39: ...ent in the sequence setting mode and then executing operation in the sequence execution mode Fig 4 7 Example of Sequence Operation The sequence setting mode has the four displays There are 10 sequence...

Страница 40: ...validity Setting items AC DC AC DC F1 ADRS Sequence address F2 R Frequency change characteristic Ramp R Step S F3 FRQ Frequency F4 R S AC voltage change characteristic Ramp R Step S F5 Vac AC voltage...

Страница 41: ...F5 Function key Mode validity Setting items AC DC AC DC F1 ADRS Sequence address F3 IMP Output impedance resistance F5 Vdc DC voltage 1 ON O F F ON A D R S S T A T T RG OU T F1 F2 F3 F4 F5 Function k...

Страница 42: ...wise manner is referred to as step In this case the frequency or AC volt age changes in a stepwise manner from the value stored in an address previous to the address specified for step to the set valu...

Страница 43: ...value using the numeric keys or JOG SHUTTLE for entry using the numeric keys press the ENTER key to confirm the value For the change characteristics each time the relevant function key is pressed R ru...

Страница 44: ...Address 0 allows no ramp specification Ramp specified for the start address is ignored and frequency or AC voltage changes in step form Starting sequence operation in the DC mode causes frequency and...

Страница 45: ...y 30 s than DC voltage Vdc Therefore output volt age changes as follows Example ADRS1 Vrms 0 V Vdc 100 V ADRS2 Vrms 100 V Vdc 0 V ADRS3 Vrms 0 V Vdc 100 V Fig 4 10 Changes in the Output Voltage in Rea...

Страница 46: ...nal board and the OUTPUT terminal board of the PCR LA series Note that the common line of each signal for the PEAK INIT IN SEQ TRG OUT and SEQ STAT OUT are not isolated because they are internally sha...

Страница 47: ...PUT terminal board and the OUTPUT terminal board of the PCR LA series Note that the common line of each signal for the PEAK INIT IN SEQ TRG OUT and SEQ STAT OUT are not isolated because they are inter...

Страница 48: ...y and set a sequence end address value using the numeric keys or JOG SHUTTLE For setting using the numeric keys press the ENTER key to con firm the value Setting is established as long as the start ad...

Страница 49: ...ll be cancelled when the power supply returns to the Home Position by pressing the ESC key When the F5 PAUSE key is pressed the sequence will be paused If the F5 key is pressed again the pause status...

Страница 50: ...quence has been executed the set number of times set OUTPUT OFF as the end address Stopping a sequence by pressing the OUTPUT key is by internally activates F1 STOP and then sets OUTPUT to OFF Therefo...

Страница 51: ...ighest frequency in frequencies which you have set When you set address set up time which did not meet the measurement cycle in sequence setting waveform of the address is not measured correctly 1 Set...

Страница 52: ...en to 85 V at 0 1 second intervals instantaneously dropped to 30 V for 0 05 second and recovered to 132 V Then 0 05 second later the voltage was ramp changed to 0 V over 0 15 second and held at 0 V fo...

Страница 53: ...4 to 13 Automatic power line environment test voltage variation instantaneous voltage drop voltage drop and voltage rise 3 ADR 14 to 15 AC DC output 50 Vrms AC at 16 Hz 48 V 48 V DC ADR R F R Vac Th T...

Страница 54: ...to call the home position 2 Press the CUR HMNC SHIFT SIM The PCR LA power supply will enter the key lock mode automat ically 3 Press the F1 ALL ODD EVEN key to select ALL all har monics ODD odd numbe...

Страница 55: ...o return to the previous display press the SHIFT MENU keys 6 Press the ESC key to return to the Home Position This will cancel the key lock mode in the PCR LA power supply Pressing the ESC key on the...

Страница 56: ...can also be read Waveform Bank The Remote Controller stores output voltage waveform data in the internal memory and generates the reference waveform for output voltage by D A conversion of such data A...

Страница 57: ...orms are backed up in the power supply Special Waveform Setting Procedure A special waveform can be set only when the OUTPUT key is OFF in the Home Position Special waveform setting is available only...

Страница 58: ...To return the peak clipped waveform to a sine wave press the F3 SIN key 7 Press the ESC key to return to the Home Position This will cancel the key lock mode in the PCR LA power supply Pressing the ES...

Страница 59: ...already ON to output the selected waveform When any waveform bank other than W00 is selected 3 lights in the PCR LA AC power supply S MODE area To return the waveform to ordinary status sine wave sele...

Страница 60: ...SC key to call the Home Position 2 Press the MODE key The PCR LA power supply will enter the key lock mode automat ically 3 Press the F3 IMP key to select the output impedance set ting mode 4 Using th...

Страница 61: ...ote Controller the power supply can operate in the same condition continuously even if the device is disconnected as long as the setting conditions remain the same For the impedance needed for harmoni...

Страница 62: ...put ON OFF Phase Setting Procedure Output impedance setting is available only in the AC mode 1 Press the ESC key to call the Home Position 2 Press the MODE key The PCR LA power supply will enter the k...

Страница 63: ...power supply S MODE area 6 Press the ESC key to exit the output ON OFF phase setting mode This will cancel the key lock mode in the PCR LA power supply Pressing the ESC key on the PCR LA power supply...

Страница 64: ...ay not be suitable for some applica tions Check the load conditions and other requirements care fully before use Regulation adjustment is not available in the power line abnormality simulation or sequ...

Страница 65: ...he voltage at the load end attains the required voltage value Fig 4 20 Adjusting the Voltage Using Regulation Adjustment 5 Press the ESC key to return to the Home Position This will cancel the key loc...

Страница 66: ...on operating procedure In addition be sure to read the Operation Manual of the PD03M S PCR LA 1 Press the ESC key to select the Home Position 2 Press the SHIFT MODE keys 3 Press the F1 key This starts...

Страница 67: ...functions Fig 5 1 RC04 PCR LA front view 1 OUTPUT key Selects output ON OFF Whenever this switch is pressed output ON OFF is switched alternately When output is ON the LED at the right of the key lig...

Страница 68: ...NTER wait This key has the same function as ENT on the PCR LA AC power supply control panel 6 SHIFT key Enables the function set in blue letters below each key If the SHIFT key is pressed the LED belo...

Страница 69: ...lights up when equipment is in the 100V range 200V lights up when it is in the 200V range When the RANGE key is pressed the range indication to be selected blinks Press the ENTER key to confirm the m...

Страница 70: ...or values in the memory 10 SEQ key Selects the sequence execution mode To start the sequence press the SEQ key Then press the F4 END key to set the end address the F3 STRT key to set start address an...

Страница 71: ...y if there are two or more displays SHIFT MENU key Selects the previous screen if there are two or more displays 15 F1 F2 F3 F4 F5 function keys Used to select the items displayed on the LCD 16 Liquid...

Страница 72: ...s for a few seconds output goes OFF This generates an alarm and sounds intermittent buzzer tones 25 Contrast Used to adjust the brightness of text displayed on the LCD 26 8 contacts mini plug con nect...

Страница 73: ...piece of soft cloth with a water diluted neutral detergent and wipe the panel gently Be sure to turn the POWER switch of the PCR LA power supply OFF before performing maintenance Do not use volatile s...

Страница 74: ...oblem Check item Results Possible causes LCD display does not appear or display content is not normal Check if the remote con troller cable has been correctly connected NO Improper remote con troller...

Страница 75: ...0 1 ms For T2 0 or T4 0 1 x10 3 1 ms T2 x1 0 ms to 9999 ms 1 ms 1 x10 3 1 ms x10 0 00 s to 99 99 s T3 x1 0 0 ms to 999 9 ms 0 1 ms For T2 T4 0 1 x10 3 0 1 ms For T2 0 or T4 0 1 x10 3 1 ms x10 0 ms to...

Страница 76: ...of AC mode DC voltage setting range is the same as that of DC mode However the peak value for AC DC voltage should be within the DC voltage setting range Same as AC and DC modes Maximum current Same a...

Страница 77: ...VA measurement 0 01 VA mini mum changes with VA value Same as that of wattmeter Power factor measurement 0 01 Same as that of wattmeter Peak holding current measurement Same as that of peak ammeter Wi...

Страница 78: ...7 4 Specifications RC04 PCR LA 7 2 Dimensions Fig 7 1 Dimension of RC04 PCR LA 40 MAX 55 128 180 Unit mm...

Страница 79: ...TER ESC Enter Output voltage mode selection Voltage setting mode F5 Vrms Vpk Vset Vavc AC DC voltage setting selection Valid only for Vset Numeric keys JOG SHUTTLE Voltage setting Digit function Valid...

Страница 80: ...mit setting mode Numeric keys or JOG SHUTTLE F5 Vmax F1 Fmax OUTPUT ESC Valid only in AC mode Current limit setting mode Current limit setting Voltage limit setting mode Frequency limit setting mode O...

Страница 81: ...display method selection Output ON OFF Exits memory operation Address setting mode ENTER Address selection JOG SHUTTLE F3 FREQ MENU Numeric keys or JOG SHUTTLE F1 ADRS F5 Vrms OUTPUT ESC F5 Vrms MENU...

Страница 82: ...tion Waveform bank setting mode Waveform bank setting Address setting mode DC voltage setting mode Memory content display method selection First screen Output ON OFF DC voltage setting mode DC voltage...

Страница 83: ...WATT SHIFT F3 F4 clr OUTPUT KEYLOCK SHIFT 4 Valid only for OUTPUT OFF RANGE SHIFT 7 SYNC SHIFT 9 KEYLOCK SHIFT 4 OUTPUT SENSING SHIFT 5 SELF TEST SHIFT 3 Valid only in event of alarm JOG ALM CLR SHIFT...

Страница 84: ...ond display F1 T1 T1 setting mode F3 T2 SHIFT 0 T3 SHIFT F5 Display selection execution display Exits the T3 setting mode POL selection SHIFT 0 SHIFT MENU Display screen selection execution display Di...

Страница 85: ...ction second display Display selection third display MENU SHIFT 0 Exits the V T3 setting mode POL selection POL selection Display selection execution display Numeric keys or JOG SHUTTLE Display select...

Страница 86: ...Sequence start Sequence restart Output OFF and sequence end Start address setting End address setting mode Loop count setting mode End address setting mode End address setting Sequence start Output O...

Страница 87: ...quency ramp specification ON OFF Display selection fourth display Output ON OFF Exits the AC voltage setting mode Exits the sequence setting mode Display selection fourth display Display selection sec...

Страница 88: ...SHIFT MENU MENU Exits the sequence setting mode Output ON OFF Display selection second display Display selection third display F1 ADRS Address setting mode Numeric keys or JOG SHUTTLE Address setting...

Страница 89: ...y selection fourth display Status signal setting Trigger signal setting OUTPUT status setting Output ON OFF F1 ADRS Numeric keys or JOG SHUTTLE Address setting mode Status signal setting OUTPUT status...

Страница 90: ...1 display 4 Output ON OFF Returns to the display mode selecting display 3 Output ON OFF Returns to the display mode selecting display 2 Output ON OFF Returns to the display mode selecting display 1 Ou...

Страница 91: ...display 6 From display 5 ESC OUTPUT MENU display 7 MENU display 8 MENU display 9 MENU display 10 MENU SHIFT MENU ESC OUTPUT SHIFT MENU ESC OUTPUT SHIFT MENU ESC OUTPUT SHIFT MENU display 9 Output ON O...

Страница 92: ...9 Output ON OFF Returns to the display mode selecting Arms display 8 Output ON OFF Returns to the display mode selecting Arms display 7 Output ON OFF Returns to the display mode selecting Arms display...

Страница 93: ...form 01 setting Valid only for SIN F3 W02 Sets waveform 02 F2 PC Note 1 Valid only for PC F3 SIN Note 2 Note 1 ESC Exits waveform 02 setting Valid only for SIN F4 W03 Sets waveform 03 F2 PC Note 1 Val...

Страница 94: ...veform 07 setting Valid only for SIN F4 W08 Sets waveform 08 F2 PC Note 1 Valid only for PC F3 SIN Note 2 Note 1 ESC Exits waveform 08 setting MENU Special waveform setting mode third display ESC Exit...

Страница 95: ...rm 13 F2 PC Note 1 Valid only for PC F3 SIN Note 2 Note 1 ESC Exits waveform 13 setting MENU Special waveform setting mode first display ESC Exits the peak clipped voltage waveform setting mode Valid...

Страница 96: ...UT ESC Exits the special waveform output mode SHIFT MENU Special waveform output mode first display F1 W05 ENTER ESC Set waveform to 05 Enter F2 W06 ENTER ESC Set waveform to 06 F3 W07 ENTER ESC Set w...

Страница 97: ...X FREE selection OFF phase setting Numeric keys OFF phase setting JOG OFF phase setting SHUTTLE OUTPUT Output ON OFF ESC Exits the ON OFF phase setting mode OUTPUT Output ON OFF ESC Exits the ON OFF p...

Страница 98: ...A 20 Appendix RC04 PCR LA A 2 Power Line Abnormality Simulation Operation Setting Sheet PCR LA Series TITLE DATE No MEMO No T1 T2 T3 T4 T5 N V T3 RPT POL MEMO...

Страница 99: ...RC04 PCR LA Appendix A 21 A 3 Sequence Operation Setting Sheet PCR LA Series TITLE DATE No START END LOOP MEMO ADR R F R Vac Th Tm Ts WAVE IMP Vdc STRT TRG OUT...

Страница 100: ...A 22 Appendix RC04 PCR LA...

Страница 101: ...M Memory function 4 6 Memory operating A 3 O Operation check 3 3 Output impedance setting 4 40 Output ON OFF phase setting 4 42 P Peak clear 4 11 Peak holding value measurement 4 11 Peak initializing...

Страница 102: ...p 4 22 T Trigger signal 4 26 V Voltage change start polarity 4 18 Voltage display mode change 4 4 Voltage setting function 4 3 Voltage current frequency and other factor setting and display operating...