4-6 Operation Method
RC04-PCR-LA
4.3.2 Memory Function
The PCR-LA AC power supplies have the memory function that
stores nine sets of voltage and frequency settings in memory
addresses up to 9 and allows them to be read for output whenever
necessary. Connecting the Remote Controller to a PCR-LA AC power
supply allows the number of set values stored in the memory (mem-
ory addresses) to be extended to 99.
The Remote Controller also offers memory operation in the AC + DC
mode, allowing simultaneous output of AC and DC voltages stored in
the same memory address. For memory addresses 1 to 9, setting is
common to both the PCR-LA AC power supply and the Remote Con-
troller.
The procedure to store data in the memory is as follows:
Memory Setting Procedure
Memory setting is available only in the Home Position.
1. Press the ESC key to call the Home Position.
2. Press the M-EDIT (SHIFT, MEN) key to enter the memory
edit mode.
3. Using the F1, F3, and F5 function keys and the MENU key,
select the desired item.
Selectable items are shown in Table 4-3. To select an item, follow
steps 4 onward.
The Setting display consists of two displays that can be switched
using the MENU key.
1
5 0 . 0 0 H z
0 . 0 V
A D R S
F R Q
V r m s
F1
F2
F3
F4
F5