RC04-PCR-LA
Operation Method 4-5
Output Voltage Mode Change Procedure
1. Press the OUTPUT key to turn output OFF.
2. Press the ESC key to call the Home Position.
The following display shows the Home Position in the Initial
Setup Status. The display differs depending on the content stored.
3. Press the AC/DC (SHIFT, 8) key to activate the ENTER Wait
status.
Each time the AC/DC (SHIFT, 8) key is pressed, the AC, AC-S,
DC, or AC + DC output voltage mode will be selected and con-
fi
rmed as shown below.
In the AC + DC mode, the AC + DC voltage peak value can be set in
the DC voltage setting range.
Fig.4-1
AC + DC Voltage Peak Value
• In the AC + DC mode, the voltage and frequency limit values
respectively set in the AC or DC modes are valid. The AC + DC
mode does not allow current limit change.
Output Voltage Setting Procedure
1. Press the ESC key to call the Home Position.
2. Press the F5 key to activate the voltage setting mode.
Each time the F5 key is pressed, the AC voltage setting mode and
DC voltage setting mode change alternately.
In the AC voltage setting mode, “AC” blinks in the MODE display
area of the device; in the DC voltage setting mode, “DC” blinks in
the MODE display area. Use the numeric keys or JOG/SHUTTLE
to set the AC or DC output voltage. For setting using the numeric
keys, press the ENTER key to con
fi
rm the value.
5 0 . 0 0 H z
0 . 0 1 A
0 . 2 V
F R Q
I r m s
V r m s
AC
DC
AC+DC
AC-S
0 V
AC + DC
voltage peak value