3-4
KLP031308
NOTE: If the front panel is unlocked by SCPI command, the unit will be set to Remote
with Local Lockout when it is turned on again. Set ANALOG I/O DIP switch posi-
tion 5 to OFF to disable Remote with Local Lockout.
3.2.3
ENABLING/DISABLING OUTPUT POWER
When the power supply is turned on, the output is automatically disabled (
DC OUTPUT
LED is
off) and the
DC VOLTS
and
DC AMPERES
displays show the programmed output voltage and
current set points and the status display reads
SET
.
To disable the output, press and release the
DC OUTPUT
switch again. The
DC OUTPUT
indi-
cator goes off.
While in the setpoint mode (Status display reads
SET
) the output cannot be turned on (pressing
DC OUTPUT
has no effect). If output was on while setpoint mode was entered, pressing
DC
OUTPUT
will disable the output.
For setpoint adjustment refer to PAR. 3.2.7.2. To enable/disable the output using analog con-
trol, refer to PAR. 3.4.1.
3.2.4
CHECKING VOLTAGE/CURRENT SETPOINTS
CAUTION: WHEN THE OUTPUT IS DISABLED, THE DC VOLTS AND DC AMPERES DIS-
PLAYS SHOW THE ACTUAL OUTPUT VOLTAGE AND CURRENT. BEFORE
ENABLING THE OUTPUT ALWAYS CHECK THE SETPOINTS TO AVOID POS-
SIBLE DAMAGE TO THE LOAD.
Check the voltage and current set points by tapping either the
VOLTAGE
or
CURRENT
control.
The status display reads
SET
, and the
DC VOLTS
and
DC AMPERES
displays show the stored
setpoints.
To accept the displayed value, tap the associated adjustment control again. To change the
value, rotate the control (press the control in while rotating for fine adjustment), then tap the
adjustment control again to accept the new setting. If you decide not to change the value after
rotating the control, the previous setpoint value will be restored after about 20 seconds of inac-
tivity, then tap either adjustment control to accept. If a fault has been configured for AUTO
recovery, the status display flashes
>AUTO
for one second upon leaving Setpoint mode (see
PAR 3.2.13.5.2).
3.2.5
PASSWORD PROTECTED FUNCTIONS
Certain functions, such as defining virtual model, system configuration, and calibration can only
be changed from the front panel after entering the unit password. Refer to PAR. 4 to change the
password. Table 4-1 shows the factory default password for each model.
1. The status display shows
PASS
(password) and the display shows
0000
with the left-most
character blinking. Rotate
CURRENT
control to select a number from 0-9. Tap
CURRENT
control to advance to next digit.
2. Repeat this process until all four digits have been selected. Tap
DC OUTPUT
switch to
accept the number. If password is incorrect, the status display reads "
ERR
". Repeat this step
to enter the correct password, or press the
FUNCTION
switch to exit.
Содержание KLP 10-150-1.2K
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP031308 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 18: ...1 6 KLP 031308 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 19: ...KLP 031308 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 24: ......
Страница 27: ...KLP HV 031308 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......