KLP031308
3-13
lems (see KLP Developer’s Guide).
•
CAL
- Display last calibration date and/or begin Calibration (see PAR. 3.2.13.7)
•
RTN
- Exit any submenu and return to previous menu
3.2.13.1 DISPLAY SYSTEM FIRMWARE VERSION
Enter
UTIL
menu (see PAR. 3.2.13, steps 1 through 3) and rotate either
VOLTAGE
or
CUR-
RENT
control until status display reads
VERS
.
• The
DC VOLTS
display identifies whether the firmware is the factory shipped firmware
(
Pri
displayed) or field updated firmware (
SEC
displayed).
• The
DC AMPS
display shows the firmware version. This information can not be changed
directly by the user.
3.2.13.2 DISPLAY MODEL
Enter
UTIL
menu (see PAR. 3.2.13, steps 1 through 3) and rotate either
VOLTAGE
or
CUR-
RENT
control until status display reads
MODL
.
• The
DC VOLTS
display shows the model voltage rating (e.g, 75.00 for KLP 75-33-1200).
• The
DC AMPS
display shows the model current rating (e.g, 33.34 for KLP 75-33-1200).
This information can not be changed by the user.
3.2.13.3 INTERNAL RELAY CONTROL
The internal relay contacts available at pins 6, 7 and 8 of the Analog I/O connector can be con-
figured from the front panel to operate in either Fault, Manual or List mode. If FAULT mode (the
factory default) is selected, the relay energizes automatically upon detection of a user-selected
condition. The selections are a)
NORM
(normal), a system fault (see PAR. 1.4.9), b)
V->C
, when
the unit transitions from Constant Voltage (CV) to Constant Current (CC) mode, or c)
C->V
,
when the unit transitions from CC to CV mode. If
V->C
(or
C->V
)
is selected, the amount of
time the unit must be in CC (or CV) mode before the relay energizes may be programmed from
the front panel (see step 2a) or using the SCPI command
OUTP:PROT:DEL
(see KLP Devel-
oper’s Guide).
1. Enter
UTIL
menu (see PAR. 3.2.13, steps 1 through 3) and rotate either
VOLTAGE
or
CUR-
RENT
control until status display reads
RELY
. The
DC VOLTS
display indicates whether the
relay is currently
ON
(energized) or
OFF
(deenergized). Tap
DC OUTPUT
switch to enter
Relay Control menu.
• Rotate either
VOLTAGE
or
CURRENT
control to see the available relay control modes
in the status display. The modes are:
FLT
(factory default) - Relay is set to energize automatically upon detection of one of
three preselected conditions:
NORM
: (factory default) relay energizes immediately upon detection of a system
(fatal) error:
V->C
: relay energizes immediately upon detection of a system (fatal) error and,
Содержание KLP 10-150-1.2K
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP031308 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 18: ...1 6 KLP 031308 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 19: ...KLP 031308 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 24: ......
Страница 27: ...KLP HV 031308 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......