3-2
KLP031308
• For -1.2K Models, the LAN indicator blinks rapidly during initialization. If an IP address
is found, it stays on without blinking. If an IP address is not found, the LAN indicator
stays off.
• If any fault is configured for AUTO recovery (see PAR. 3.2.13.5.2), the status display
flashes
AUTO
for one second.
• If remote inhibit is active (see PAR. 3.4.1) upon power-up, the status display flashes
rINH
for one second.
• If an error occurs, an error code is displayed in the status display (see Table 3-1).
3. After a successful self test, the default conditions upon power up are as follows:
• Status display shows
SET
,
• output is disabled (green
DC OUTPUT
indicator is off). If remote analog mode is
selected (PAR. 3.4), output is enabled unless Remote Inhibit, pin 8 of the Analog I/O
Connector (see Figure 2-2 and Table 2-7) is grounded.
•
DC VOLTS
and
DC AMPERES
displays show programmed output conditions: either 0
Volts, minimum Amperes (see NOTE, PAR. 3.2.1) or, if DIP switch position 3 enabled
(see Table 2-2), previously saved setpoint values in effect upon power off.
NOTE: A minimum programmed current is required to ensure proper operation of the power
supply under all load conditions. Programmed current is automatically set to be at least
the minimum current (actual value depends on model, see Table 1-1).
• Since the output is off, Constant Voltage (
CV
) mode indicator (green LED) and Con-
stant Current (
CC
) indicator (amber LED) are off.
TABLE 3-1. POWER-UP BUILT-IN TEST ERROR CODES
ERROR CODE
MEANING
E310
System Error
E313
Calibration Memory Error
E315
Configuration Memory Error
E341
Memory Error (CRC)
E330
Self Test Error
Ecal
Calibration Error - The unit will try to restore the previous calibration.
Eclp
Previous Calibration Error - After detecting a Calibration Error (Ecal) and trying to use
the previous calibration, an error was detected, and the unit will attempt to restore the
factory calibration.
Eclf
Factory Calibration Error - The unit has failed to restore the factory calibration after
failing to restore the previous calibration. The unit will not operate after this error has
been displayed and must be referred for service.
NOTE: During power-up the power supply performs detailed software check sequences. If a failure is detected dur-
ing power-up, the DC VOLTS and DC AMPERES displays are blanked and the Status display shows an error code.
For errors that occur after power-up, refer to the Developer’s Guide for typical error codes and possible causes. For
these and all other error codes, refer to authorized service personnel if corrective action is required.
Содержание KLP 10-150-1.2K
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP031308 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 18: ...1 6 KLP 031308 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 19: ...KLP 031308 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 24: ......
Страница 27: ...KLP HV 031308 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......