KLP-HV 031308
2-5
TABLE 2-5. LAN PORT CONNECTOR (J7) PIN ASSIGNMENTS [-1.2K MODELS ONLY]
PIN
SIGNAL NAME
FUNCTION
1
TX+
Tr
2
TX–
Transmit –
3
NOT USED
4
NOT USED
5
NOT USED
6
NOT USED
7
RX+
Receive +
8
RX–
Receive –
TABLE 2-6. CONTROL INPUT TERMINAL BLOCK ASSIGNMENTS
TERMINAL
FUNCTION
M+
Positive output monitor connection (TB5) (see PAR. 2.7.5.1)
S+
Positive sense connection (TB4) (see PAR. 2.7.5.1)
CS
Current Share bus (TB3) (see PAR. 2.7.7.1)
S-
Negative sense connection (TB2) (see PAR. 2.7.5.1)
M-
Negative output monitor connection (TB1) (see PAR. 2.7.5.1)
TABLE 2-7. ANALOG I/O CONNECTOR (J2) PIN ASSIGNMENTS
PIN
SIGNAL NAME
FUNCTION
1
Cref
Analog signal which programs output current from zero to full scale. Voltage or resistance programming
is selected via DIP switch position 2 (See Table 2-2). Refer to PAR. 3.4.3 for voltage programming and
3.4.2 for resistance programming.
2
RELAY_NO
Connected to RELAY_COM (pin 4) for relay energized condition. (1)
3
Vref
Analog signal which programs output voltage from zero to full scale. Voltage or resistance program-
ming is selected via DIP switch position 1 (See Table 2-2). Refer to PAR. 3.4.3 for voltage programming
and 3.4.2 for resistance programming.
4
RELAY_COM
Relay common. (1)
5
Reserved.
6
VOLT_RBACK
Analog signal which represents output voltage from zero to full scale. The full scale programming level
sets the full scale readback level (see PAR. 4.3.3).
7
CURR_RBACK
Analog signal which represents output current from zero to full scale. The full scale programming level
sets the full scale readback level (see PAR. 4.3.3).
8
REM_INH
Allows single signal to control output on/off. See PAR. 3.4.1.
9
GND
Ground
(2)
10
RELAY_NC
Connected to RELAY_COM (pin 4) for relay not energized condition (1)
11
GND
Ground
12
ANALOG_CTRL
Enables or disables analog programming (see PAR. 3.4).
1 = Analog programming disabled (default, no connection)
0 = Analog programming accepted (use jumper on mating connector to connect to pin 9, 11, 13 or 15
(ground).
13
GND
Ground
14
EXT_TRG
Performs same function as SCPI *TRG command if unit is programmed for external triggering via digital
remote mode. Transition from 1 (+5V) to 0 (ground) causes values established by VTRIG and CTRIG
commands to become VSET and CSET (see PAR 3.3.2, External Triggering).
15
GND
Ground
(1) Refer to PAR. 3.2.13.3 to configure internal relay.
(2) All GND connections are common.
Содержание KLP 10-150-1.2K
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP031308 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 18: ...1 6 KLP 031308 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 19: ...KLP 031308 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 24: ......
Страница 27: ...KLP HV 031308 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......