KLP-HV 031308
2-1
SECTION 2 - INSTALLATION
2.1
UNPACKING AND INSPECTION
This instrument has been thoroughly inspected and tested prior to packing and is ready for
operation. After careful unpacking, inspect for shipping damage before attempting to operate.
Perform the preliminary operational check as outlined in PAR 2.5. If any indication of damage is
found, file an immediate claim with the responsible transport service.
2.2
TERMINATIONS AND CONTROLS
2.2.1
FRONT PANEL CONTROLS AND INDICATORS.
Refer to Figure 2-1 and Table 2-1.
FIGURE 2-1. KLP SERIES, FRONT PANEL CONTROLS AND INDICATORS
2.2.2
REAR PANEL CONNECTORS AND SWITCHES.
Refer to Figure 2-2 and Tables 2-2 through
2-7.
TABLE 2-1. CONTROLS, AND INDICATORS
CONTROL OR
INDICATOR
FUNCTION
POWER ON/OFF
Circuit Breaker
Turns the power supply on or off. Applies input power to power supply internal circuits. Circuit breaker
provides input overload protection.
VOLTAGE
control/switch
Multifunction rotary encoder with momentary-contact pushbutton switch. Rotate to set output voltage
(PAR. 3.2.7) and overvoltage limit (PAR. 3.2.8). Also used to enter SET mode of voltage programming
(PAR. 3.2.7.2), change GPIB address (PAR. 3.2.9), change RS232 baud rate (PAR. 3.2.10), enter Vir-
tual Model password (PAR. 3.2.6), and enter calibration password and perform calibration (PAR. 4.3).
DC VOLTS
display
Four-digit LED display that shows voltage settings:
a. Shows actual output voltage (default).
b. Shows voltage set point (PAR. 3.2.7.2) or overvoltage limit when function selected (PAR. 3.2.8).
CV
indicator
Green LED lights to indicate power supply is operating in constant voltage mode (see PAR. 3.2.7).
Status
4 character display
Displays active function or blinks for error messages. Normally blank (VOLTAGE and CURRENT
LEDs display actual voltage and current).
CC
indicator
Amber LED lights to indicate power supply is operating in constant current mode (see PAR. 3.2.7).
POWER ON/OFF
Circuit Breaker
VOLTAGE
control/momentary switch
DC VOLTS
display
CV
indicator
Status
display
CC
indicator
DC AMPERES
display
CURRENT
control/momentary switch
DC OUTPUT
indicator
DC OUTPUT
on/off switch
PROTECT
momentary switch
LAN
indicator
[-1.2K Models only]
FUNCTION
momentary switch
Содержание KLP 10-150-1.2K
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP031308 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 18: ...1 6 KLP 031308 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 19: ...KLP 031308 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 24: ......
Страница 27: ...KLP HV 031308 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......