KLP031308
3-17
1. Enter
UTIL
menu (see PAR. 3.2.13, steps 1 through 3) and rotate either
VOLTAGE
or
CUR-
RENT
control until status display reads
SYST
, then tap
DC OUTPUT
switch. Rotate either
VOLTAGE
or
CURRENT
control to until the status display reads
RCOV
.
The
DC VOLTS
and
DC AMPERES
displays show a series of bars that give a snapshot pic-
ture of the recovery configuration as defined in Figure 3-1. The location of the bar (top, mid-
dle, or bottom) corresponds to the risk level (high for AUTO, middle for SAFE, and low for
PROTECT). The character positions are assigned to the configurable faults as shown.
FIGURE 3-1. FAULT RECOVERY CONFIGURATION DISPLAY
2. To change a fault recovery setting, tap the
DC OUTPUT
switch to enter the Recovery menu.
3. The status display shows
PASS
. Enter the unit password (see PAR. 3.2.5) and tap
DC OUT-
PUT
switch to accept the number. When the password is accepted, status display reads
OVP
and the
DC VOLTS
display shows the present fault recovery status (
PROT
or
SAFE
) for
OVP
.
Rotate either
VOLTAGE
or
CURRENT
control to cycle through
OVP
,
OCP
,
OLF
,
TEMP
, and
PWR
settings. To exit tap the
DC OUTPUT
switch while the status display shows
RTN
.
4. To change a setting, tap the
DC OUTPUT
switch while the status display shows the fault.
The setting in the
DC VOLTS
display begins to blink. Rotate either
VOLTAGE
or
CURRENT
control to cycle through the allowable settings. Tap the
DC OUTPUT
switch to accept the
setting shown in the
DC VOLTS
display.
5. To continue, rotate either
VOLTAGE
or
CURRENT
control to select another fault. To exit,
either select
RTN
and tap the
DC OUTPUT
switch to go to the next highest menu, or tap the
FUNCTION
switch to exit function mode.
3.2.13.6 ANALOG INPUT FULL SCALE CALIBRATION
Enter
UTIL
menu (see PAR. 3.2.13, steps 1 through 3) and rotate either
VOLTAGE
or
CUR-
RENT
control until status display reads
INVC
.
• The
DC VOLTS
display shows the analog input voltage value that produces the full
scale output voltage established by the virtual model.
• The
DC AMPS
display shows the analog input voltage value that produces the full scale
output current established by the virtual model.
1. To change the settings tap the
DC OUTPUT
switch.
2. Rotate
VOLTAGE
control to set the analog voltage value required to produce the full scale
output voltage (for fine adjustment press in
VOLTAGE
control and hold while rotating).
3. Rotate the
CURRENT
control to set the analog voltage value required to produce the full
scale output current (for fine adjustment press in
CURRENT
control and hold while rotating).
NOTE:
THE FOLLOWING SETTINGS ARE SHOWN:
PWR SET TO AUTO
TEMP SET TO AUTO
OLF SET TO PROTECT
OCP SET TO PROTECT
OVP SET TO SAFE
Содержание KLP 10-150-1.2K
Страница 2: ......
Страница 6: ......
Страница 12: ...vi KLP031308 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Страница 18: ...1 6 KLP 031308 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 R DWG MECH 3010266...
Страница 19: ...KLP 031308 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 24: ......
Страница 27: ...KLP HV 031308 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Страница 40: ......