JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
74
/
110
MLJ51410
Alarm call
– a group of reports in the case of which (after sending of SMS reports) the system conveys
an alarm voice message to the user. The call rings for approx. 30 sec. If the call is not answered, the system
calls the next user in sequence. If the call is answered, the voice message is sent repeatedly. The structure
of the message is: Your alarm reports – Alarm type – Section no. After hanging up of the call by the user,
however after 50 s at the latest, the call is terminated and the next user is called. The user can confirm
the reception of the call by pressing the
# key
on the phone and after the voice message the user must enter
a valid code. When a valid code has been entered,
the alarm is stopped and the next user is not called any
more.
Voice calling is time-consuming and it can be set for a limited number of users (JA-101K-xx - 8 users /
JA-106K-xx - 15 users). For the voice reports universal voice message are pre-set in the system. The voice
messages can be re-recorded by replacing the names with the required ones in the voice menu. Voice menu
structure, see 9.5.
SMS about setting / unsetting
– group of reports for which a text message about setting and unsetting
is sent. A setting report is sent with the fixed
delay of 60 seconds
after setting. Setting and unsetting
is not reported to the user who has performed it. An exception is setting of a common section (done
by the control panel, not user).
Photo
– sends the user an SMS saying that an alarm photo has been taken if photo-veryfication devices are
installed. More details - see manuals of the respective camera detectors.
Fault and service SMS
– sends text reports about errors (discharged batteries, entering the Service mode
etc.).
User defined 1
– special 1st group where the installation technician may transfer certain events to be reported
(typically reports of failures and restoration of power supply, or possibly setting with an active device) only
for selected users (administrator etc.)
User defined 2
– special 2nd group where the installation technician may transfer certain events
to be reported (typically low batteries in devices or low charge level of the backup battery) only for selected
users (typically installation technician etc.).
Reports from sections
– determines which section the selected groups of events will be reported from.
If Errors and Service SMS are checked and no section is selected, system errors and service are reported only
(they are always assigned to the Section no. 1). There is no link between authorization and the ability of section
control.
PG enabled SMS*
– possibility to report enabling of PG outputs to a user. The messages are sent with a fixed
delay of 60 s. The texts of the SMS messages are set in the PG Outputs tab, see chapter 10.7 PG outputs tab.
PG disabled SMS*
– possibility to report disabling of PG outputs to a user. The messages are sent with
a fixed delay of 60 s. The texts of the SMS messages are set in the PG Outputs tab, see chapter
10.7 PG outputs tab.
Special Reports SMS
* – possibility to report activation of detectors for which the Special Report reaction
(A, B, C or D) has been set to the user with an SMS. The texts of special reports are set using the
Special
Reports
button on the right at the bottom of the Reports to users tab.
Special Reports by voice
* – possibility to report activation of detectors for which the Special Report reaction
(A, B, C or D) has been set to the user with a voice message. Voice messages can be re-recorded by calling
to the phone number of the control panel where after answering of the call and authorization with
the administrator’s code you can use the key 9 to enter recording of voice messages, see chapter 9.5 System
control via communicator voice menu (GSM / PSTN). Basic menu of the JABLOTRON 100 voice communicator:
Test
– by pressing of this button the test SMS report will be sent to the user: „Test report, Control Panel,
Section 1“