JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
32
/
110
MLJ51410
digit valid access code (for instance. 12*3456). In this case it is allowed for users to enter their own 4-digit codes
from an LCD keypad and to edit them arbitrarily. Disabling the function causes the system not to require a prefix
to be entered and only a valid access code is required. In this case only the system administrator can add and
edit the codes of all users. The administrator has to avoid the situation of code duplication (2 users should not
have the same code).
Caution: disabling this parameter causes the irreversible erasing of all user codes and pre-set service and
administrator codes to default values. User authorization and RFID cards and tags of already set up users
remain the same.
Code length
– to increase the alarm system security level during authorization, it is possible to pre-set the
user code length regardless of the prefix function. There can be 4,6 or 8-digit codes. When the code length
is changed, then Service and Administrator codes are set to the default values (1010 and 1234) and all other
codes are erased. Default codes are:
Default codes with a prefix
4-digit
6-digit
8-digit
Service:
0*1010
0*101010
0*10101010
Administrator:
1*1234
1*123456
1*12345678
Default codes without a prefix
4-digit
6-digit
8-digit
Service:
1010
101010
10101010
Administrator:
1234
123456
12345678
Enable 125 kHz EM UNIQUE card standard -
If disabled, identification RFID cards / tags (JA-190J, JA-191J,
JA-192J, JA-194J) recommended by the manufacturer may only be used. Cards of other manufacturers working
at the above-mentioned frequency are also allowed.
Siren when partially set IW
– This function which allows the activation of internal sirens during an intrusion
alarm (it is not related to Fire or 24hr alarms) when the system is partially set.
Warning about default codes -
When service mode is left the system sends an SMS (position 0)
to the service technician about the remaining codes still set to default.
Administrator – restricted Service / ARC rights
- Administrator authorisation is required to access
the system for the ARC or service technician. In the case of remote access by a service technician
to the system via F-Link the administrator may get authorised using a keypad in the building. In the case
of a local connection by a service technician to the control panel using a USB cable the administrator may get
authorized remotely using the voice menu.
Service and ARC controls the system
- This is for the service and ARC technicians to control (Set / unset)
all sections and all PG outputs (ON / OFF) who require authorisation.
Trial operation
– A special mode used after system installation when, regardless of the real setting of alarm
length, it shortens to 60 sec and all alarm event are reported by means of an SMS to defined users and the service
technician (position 0) even though alarm reports are not activated for them. Test operation is automatically
terminated after 7 days after leaving Service mode.
Service requirement
- If enabled, 12 months after you have left service mode there appears on the LCD
keypad a message namely “System check requirement“ and by pressing the „i“ button it shows “call service
technician” with his telephone number (if pre-set). A message on the LCD disappears automatically when
a service technician locally accesses the system. The annual check counter performs a reset.
Duress access control
– This function is to trigger a silent panic alarm by authorization only or during system
control (setting, unsetting, PG) when a user is under pressure from an intruder. A panic alarm is triggered during
system control by adding the number „1“ to the last digit of the code. It is supported for a code with or without
a prefix as well. When a user code has the number 9 as the last digit then during access control enter 0
as the last digit.
Alarm confirmation within one section
- If confirmation reaction by another detector is set for a detector,
this confirmation option can be used to limit confirmation
to the same
section only (otherwise a detector from any
section can confirm an alarm). This is equally valid for intrusion detectors and for fire detectors.
Siren (IW output) when tamper is triggered
- The sirens with an IW reaction acoustically indicate a tamper
alarm if the zone is unset or partially set. Sirens always indicate when the system (section) is set fully.
Tamper alarm indication reset by Service
- The tampering memory indication can only be reset by a service
or ARC technician. If this option is not checked, the indication may also be reset by the Administrator (but not a User).
Reset enabled
- Possibility to lock resetting the control panel with a jumper on the board. If the reset option
is disabled and the service code is lost, the control panel can only be unlocked by the manufacturer.
Reset of the control panel is described in chapter 12 Reset of the control panel.