JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
53
/
110
MLJ51410
9.13 Overview table of Groups of Events reported to users
All events which are sent to users (35) are assigned to 5 basic groups. Every single group can be assigned to
users arbitrary. Users to whom a group will be assigned will be sent reports from this group. When the basic
settings of the groups are not enough then there are two special groups which can be used. User defined group
1 and 2. Events can be added to those groups and can be given to only specific users.
Overview table:
Order
Event
Group
1
Setting
SMS about Setting / Unsetting (3)
2
Unsetting
SMS about Setting / Unsetting (3)
3
Partially setting
SMS about Setting / Unsetting (3)
4
30 minute mains fault
SMS alerts (1) / Alarm call (2)
5
Mains restored after 30 min
SMS alerts (1) / Alarm call (2)
6
Instant alarm
SMS alerts (1) / Alarm call (2)
7
Instant alarm cancelled
SMS alerts (1) / Alarm call (2)
8
Delay alarm
SMS alerts (1) / Alarm call (2)
9
Delay alarm cancelled
SMS alerts (1) / Alarm call (2)
10
Tamper alarm
SMS alerts (1) / Alarm call (2)
11
Tamper alarm cancelled
SMS alerts (1) / Alarm call (2)
12
Fire alarm
SMS alerts (1) / Alarm call (2)
13
Fire alarm cancelled
SMS alerts (1) / Alarm call (2)
14
Panic alarm
SMS alerts (1) / Alarm call (2)
15
Panic alarm cancelled
SMS alerts (1) / Alarm call (2)
16
Health troubles
SMS alerts (1) / Alarm call (2)
17
Flooding
SMS alerts (1) / Alarm call (2)
18
Code breaking attempt
SMS alerts (1) / Alarm call (2)
19
Set with active zone (when confirmation enabled)
SMS alerts (1) / Alarm call (2)
20
Section without movement
SMS alerts (1) / Alarm call (2)
21
System start (out of service mode)
Fault and service SMS (5)
22
Device low battery
Fault and service SMS (5)
23
Device battery OK
Fault and service SMS (5)
24
Fault (device, communicator)
Fault and service SMS (5)
25
Fault end
Fault and service SMS (5)
26
Service mode entry
Fault and service SMS (5)
27
Service mode left
Fault and service SMS (5)
28
Low BATTERY
Fault and service SMS (5)
29
BATTERY OK
Fault and service SMS (5)
30
ARC communication fault
Fault and service SMS (5)
31
ARC communication restored
Fault and service SMS (5)
32
RF jamming
Fault and service SMS (5)
33
RF jamming end
Fault and service SMS (5)
34
Low credit balance
Fault and service SMS (5)
35
Alarm photo
Photo (4)
The assignment of events distinguished by the system to groups is specified in the table. On occurrence of an
event the system generates an SMS in the format:
Installation name
(see the Initial setup tab):
Time
(of event occurrence),
Event
(see table).
Event source
(see the Device/Name or User/Name tab),
Section
(where the event occurred); (in case of
more events they are arranged one after another in one message separated with semicolons);
Time
(time and date of sending)
Example of a sent SMS:
JABLOTRON 100
(installation name)
17:01:10, Delayed alarm
(event time, event)
Door magnet, Ground floor
(detector name, section name)
17:01:25, Instant alarm
(event time, event)
Staircase movement, Upstairs
(detector name, section name)
Time 17:01 22.7.
(time of sending)