JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
64
/
110
MLJ51410
with a new one. The Import button offers you the history of the last known settings of the keypad at that given
position.
Authorization
– the user’s authorization is required for setting and unsetting. When this parameter
is disabled, all segments can be controlled without authorization except the Unset Section function for which
authorization is always required. As regards enabling and disabling PG outputs the setting of the Authorization /
without Authorization function is valid for both the controls.
Segment functions
– on the left the function of the segment is selected, on the right the section or PG output
that the selected function is assigned to. The following functions can be assigned to a segment:
None
Segment off, used for segments prepared as a reserve for future used
Unset / Set
Section control. Segment indication: section unset = green, set = red
Unset / Partly
set
Enables activation of partial setting mode of the section (if enabled in the Sections tab).
Segment indication: section unset = green, partially set = yellow
Unset / Partly
set / Set
Allows you to select the setting level. After pressing of the right button (Set) partial setting
is offered, after repeated pressing complete setting is offered. For this selection partial
setting must be enabled for the section in the Sections tab.
Segment indication: section unset = green, partly set = yellow, fully set = red.
Indicates
section
The segment only shows the status of the section, but does not enable its control (suitable
e.g. for indication of the status of common sections, staircase etc.) If an alarm is released,
it allows you to cancel it by pressing the green button of the segment with subsequent
valid authorization of the user.
Panic (silent)
The segment makes it possible to release a silent Panic alarm. After pressing the right
button a Panic report is sent from the section the function is assigned to, without acoustic
indication. The Panic alarm may also be Delayed with adjustable time and possibility of
cancellation before expiration of the set time (see Delayed Panic). If the section is set,
it will not be unset.
Fire
The segment triggers the fire alarm. Then, fire alarm is released from the section
the segment is assigned to.
Audible Panic
The segment makes it possible to release a loud alarm. After pressing, loud Panic alarm
is released from the section the segment is assigned to. The loud Panic alarm may also
be Delayed with adjustable time and possibility of cancellation before expiration of the set
time (see Delayed Panic). If the section is set, it will not be unset.
Medical
troubles
The segment allows you to send a health problem report (without activating a siren).
Then, the segment returns to the standby mode and the system sends the Medical trouble
report from the section the segment is assigned to.
Disable PG /
Enable PG
The segment allows you to control a PG output. Indication: PG inactive = green, PG
active/enabled = red
Enable PG
The segment can only be used to enable the PG output (e.g. switch on the lights for
a pre-set time)
Disable PG
The segment can only be used to disable the PG output (e.g. function of an emergency
STOP button)
Indicates PG
The segment only indicates the status of the PG output without the possibility to control
it (red indicates the active status)
Indicates PG
inversely
The segment only indicates the status of the PG output with the inversed logic
(green indicates the active status) without the possibility to control it
Common
segment A / B
Enables simultaneous control of more sections that have their individual segments
on the keypad with one segment. After pressing the button on the same segment
the Unset/Set command is executed collectively for selected section segments. If some
sections controlled from the Common Segment are set and the others unset, after using
the Common Segment the remaining segments will be Unset/Set. If Partial Setting
is enabled for one of the selected segments (details see 9 System control options),
the Common Segment will behave as follows: 1st pressing of Set = partial setting,
2nd pressing of Set = full setting. It is not suitable to combine the Common Segment
function with the Section / Common for Sections functions.
Common Segment indication: all sections unset = green, all sections fully set = red, any
section set (party set) = yellow.
There may be max. 2 common segments on one keypad at the most.
Sections are assigned to the Common Segment in the top Common Segment tab.