Functions:
RFID reader
To save energy, the activity of the reader can only be limited to 3 s from pressing of its
cover. The RFID reader can also be completely disabled. This setting applies to wireless
keypads and access modules if they are permanently supplied with power from
an external source, otherwise their RFID reader is always switched off automatically
Permanently on
The RFID reader is permanently enabled. In the case of a BUS
keypad it does not respect the wake-up setting.
Enabled by
pressing
Waking up the RFID reader for 3 s after activation on the keypad.
Off
The RFID reader is permanently disabled.
Optical indication
settings
1. Indicates
permanently
A BUS keypad indicates permanently. A wireless keypad will only
indicate permanently with external power supply. Without external
power supply it behaves like in option 2.
2. After a
section status
change on the
keypad
The keypad indicates a change of the status of a section / PG.
A status change is only indicated on the concerned segment. An
entry delay and alarm are indicated by the whole keypad.
3. After a
section status
change on the
segments
The keypad indicates a change of the status of a section / PG.
A status change of a segment, entry delay and alarm are only
indicated on the concerned segment.
4. After a
segment status
change
Entrance delays and alarms are just indicated acoustically. A status
change is only indicated on the concerned segment. This option
is the default setting.
5. After an entry
and alarm
The keypad indicates an entrance delay and alarm on the concerned
segment. A change of the PG output status and section status are
not indicated at all.
6. Wake-up by
pressing
The keypad only provides optical and acoustic indications after
opening of the front cover; pressing of a key, segment or front cover
Indicates PG status changes
Optical indication of a PG´s output status changes on a segment. It is related
to the indication settings – options 2 – 4. If disabled, the PG output status
changes are not optically indicated.
Indicates Unset status
Keypad segments indicate an unset status without valid authorization.
When disabled, they indicate this status only during valid authorization.
Indicates Set status
Keypad segments indicate a set status without valid authorization.
When disabled, they indicate this status only during valid authorization.
Unset section by
authorization only during
entrance delay
If enabled, then a section where the entrance delay has started is unset
by a user valid RFID card/tag or code authorisation only. With wireless
keypads authorization can be performed after the entrance delay is triggered.
CAUTION: We strictly recommend you to disable this function when
the entrance delay usually runs for a common section, otherwise all sections
assigned to the common section will be unset for a given authorisation.
The segments where the entrance delay doesn´t run can also be unset.
Select the button for unsetting on the relevant segment button before you
authorise yourself.
LCD backlight goes off in 5 s
If enabled, the LCD backlight goes off 5 sec after the last time of operation
with a unit (pressing a key, segment or front cover). If disabled the backlight
goes off at the same moment as the whole keypad. If enabled then the battery
lifetime is increased.
Delayed panic
The function serves to postpone triggering of a silent or audible panic by
a pre-set time. It is possible to determine the time interval when you can
cancel the activation by repeated pressing of the same segment button with
a pre-set to silent or audible panic. By pressing the right (red) button the timer
is triggered and by pressing the left (green) button it is cancelled.
When authorization is enabled then it is required for activation and
deactivation as well. The delay is adjustable from 1 sec to 255 sec.