F I L L I N G A N D A D J U S T I N G O I L E R
The oiler ensures that the hoist air supply is consistent-
ly provided with a precisely-metered quantity of oil.
Regular checking of the oiler is very important, as the
vane motor may be damaged in the case of lubricant
deficiency. The oiler can also be refilled under pressure.
Check the oil level through the sight glass in the
container. The oil level must not fall below the mini-
mum mark.
Remove the oil filler screw.
Fill the container with oil up to the maximum mark
and refit the oil filler screw.
Check the oil drop rate at the sight glass with the
motor running.
Turn the oil throttle screw using a screwdriver until
the desired number of drops per minute is achieved.
Turning clockwise reduces the amount of oil; turning
anti-clockwise increases the amount of oil.
Oil drop rate (lifting without load):
2 drops per minute.
C AU T I O N !
Operation of service units with synthetic
oils is not permissible.
They must also not be connected to com-
pressed air circuits, which are supplied by
compressors lubricated with synthetic oil.
WA R N I N G !
J.D. Neuhaus only supplies standard spray
oilers.
Do not use microspray oilers as very finely
secreted oil spray could adversely effect the
surrounding air and therefore the respiratory
system.
Check oil drop rate at sight glass and adjust
Oil filler screw
Sight glass
Oil throttle screw
Check the oil level and top up if necessary
maximum
oil level
minimum
oil level