powered by air !
P R O D U C T I N F O R M AT I O N
Page 14
T E M P E R AT U R E L I M I T S F O R E X P L O S I O N -
H A Z A R D O U S D U S T S
In areas which are explosion-hazardous due to com-
bustible dusts, the surface temperature must not exceed
two-thirds of the ignition temperature in ° C of the
dust/air mixture. The temperatures of surfaces on which
hazardous deposits of combustible dusts can be formed,
must not exceed the glow temperature of the relevant
dust minus 75K. Greater safety margins are required if
the thickness of the dust layer exceeds 5 mm.
P L E A S E AL S O O B S E R VE YO U R
C O R R E S P O N D I N G N AT I O N AL
R E G U L AT I O N S .
The corresponding surface temperatures can be derived
from the lowest values for glow and ignition
temperatures of dusts specified in the HVBG/BIA Report
12/97
10
”Combustion and explosion characteristics of
dusts”:
Synthetic rubber, soot-containing:
Glow temperature 220° C – 75° C = 145° C max.
permissible surface
temperature
Stearic acid:
Ignition
190° C x 2/3 = 126° C max.
temperature
temperature
permissible surface.
1
Guideline 94/9/EC of the European Parliament and the Council dated 23rd March 1994 on the adaptation of the laws
of the Member States concerning equipment and protective systems intended for use in potentially explosive
atmospheres
2
DIN EN 1127-1: Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and
methodology, 1997-10
3
IEC 60079-12: Electrical apparatus for explosive gas atmospheres, Part 12: Classification of mixtures of gases and
vapours with air according to their maximum experimental safe gaps and minimum igniting currents, 1978
4
IEC 60079-20: Electrical apparatus for explosive gas atmospheres,
Part 20: Data for flammable gases and vapours relating to the use of electric apparatus, 1996-10
5
EN 13463-1: Non-electrical devices intended for use in explosive areas - part 1: Basic methodology and requirements,
07/2009
6
DIN VDE 0165: Installation of electrical systems in areas with explosion hazard, 1991
7
Redeker, Schön: 6. Supplement to safety-related characteristic values for flammable gases and vapours, 1990
8
Nabert, Schön: Safety-related characteristic values for flammable gases and vapours, 2nd edition, 1978
9
DIN EN 50014 (VDE 0170/0171 part 1): 2000-02
Electrical apparatus for use in explosion hazardous areas: General provisions
10
HVBG/BIA report 12/97: Central association of German employer’s liability associations /trade association institute
for industrial safety
Содержание Profi 025Ti
Страница 1: ...powered by air J D N O P E R A T I O N M A N U A L A I R H O I S T S...
Страница 65: ...powered by air NOTES Page 65...
Страница 66: ...powered by air NOTES Page 66...
Страница 67: ...powered by air NOTES Page 67...
Страница 217: ......