AT T E N T I O N !
If a hoist is operated with a service unit,
this should not be mounted further than 5 m
away from the hoist.
The ambient temperature must be a minimum of
0° C. It must not exceed 50° C.
N O T E :
If, at the request of the customer, a service unit
is installed in hoists in motorised trolleys and lifting
gear, it will be configured at the factory.
The service unit in the Air Hoists PROFI O25 TI to
PROFI 2 TI consists either of two elements, filter
controller and oiler, or of the filter controller only.
C H E C K I N G A N D A D J U S T I N G T H E F I LT E R
CO N T RO L L E R
* )
The filter controller is set to an actual pressure of 5.4
bar (3.6 bar) in the factory (actual pressure with motor
running).
In this setting, the manometer can indicate a pressure
of over 6 bar (4 bar) with the motor switched off. For
correct adjustment, a pressure of at least 7 bar (5 bar)
upstream of the service unit is required.
Lift the regulator knob.
Turn the regulator knob until the manometer
indicates a pressure of 5.4 bar (3.6 bar).
Clockwise: higher pressure
Anti-clockwise: lower pressure
Lock the regulator knob by pressing it down.
Alternatively, the filter controller can be set to a pres-
sure of 6 bar (4 bar) in the absence of an air stream.
This setting is only correct for a pressure of at least 7
bar (5 bar) upstream of the service unit.
Depressurise the air line downstream of the service
unit and close it again.
Turn the regulator knob anti-clockwise, in order to
release the adjusting spring.
Turn the regulator knob until the manometer indi-
cates a pressure of 6 bar (4 bar).
Clockwise: higher pressure
Anti-clockwise: lower pressure
Lock the regulator knob by pressing it down.
If the nominal pressure of 5.4 bar (3.6 bar) cannot be
achieved despite a sufficiently high pressure upstream
of the service unit, then the air line cross-section is too
small.
* )
Values for 4-bar hoists in brackets
adjusting knob
lubricator
filter-regulator
Filter controller and oiler
S E R V I C E U N I T
powered by air !
M A I N T E N A NC E