D R A I N I N G CO N D E N S AT E
After a certain time, condensate collects in the filter
regulator container, which must be regularly drained.
Check the condensate level through the sight glass in
the filter container. The condensate level must not
reach the separating plate.
The container can be emptied manually or semi-automa-
tically, depending on the setting of the drain valve:
OFF position
The drain valve is closed in this position.
The OFF position is generally set at the factory.
ON position
The condensate can be drained manually in this posi-
tion. Operate the drain valve by pressing upwards
(see Figure).
When the compressed air supply is connected, the
drain valve is under pressure. We recommend using
suitable splash protection (cloth, fleece) as the con-
densate will otherwise escape uncontrollably.
Collect the escaping condensate and dispose of it as
it may contain oil.
AUTO position
In this position, semi-automatic condensate drainage
takes place. When the pressure upstream of the servi-
ce unit falls below 0.2 bar, the container empties
automatically. With this setting it must be ensured
that a suitable container is in place to collect the
escaping condensate when drainage occurs.
C L E A N I N G T H E F I LT E R E L E M E N T
AT T E N T I O N
Do not use alcohol for cleaning the service
unit. Alcohol can damage parts of service
unit. Transparent components must only be
cleaned using soap solution.
The filter element must be cleaned once annually.
For this purpose, proceed as follows:
Drain the water.
Shut off the main air supply and carefully allow the
residual pressure to dissipate.
Unlock the filter regulator container, turn anti-clock-
wise to the stop and remove.
Unscrew the separating plate. The filter is located
loosely on the separating plate centring device.
Clean the filter element using soap solution and blow
through forcefully.
Reinstall the clean filter element and fasten the
separating plate.
Insert the filter regulator container in the housing
and turn clockwise. The container locks
automatically.
Cleaning the filter element
powered by air !
M A I N T E N A NC E
Page 48
filter element
separating disc
sight glass
filter receptacle