powered by air !
M A I N T E N A NC E
Page 43
The specified inspection intervals are valid for use in accordance with the classification (see driving mechanism classi-
fication on the nameplate). The service life is approx. 10 years if the device is used in accordance with its classification.
If the hoist is used more intensively the intervals are to be shortened accordingly. The intensity of use must be assessed
using the
model for determining the actual operating time
(see page 41). All operating hours are translated into full
load hours. The theoretical operating time and the interval hours are indicated in full load hours.
Maintenance measure
Interval
Comment
Check oil level for motor lubrication
Daily
(
Filling and adjusting oiler
section, page 49)
(when operating with oiler)
Lubricate chain
As required
(
Lubricating the chain
section, page 45)
Visually check the chain
Weekly
Inspection measure
Interval
Comment
Check control device
Daily
(
Checking controls
section, page 46)
Check the braking function
Daily
(
Checking braking function section,
page 45)
Checking direction of movement
Daily
(
Checking direction of movement section,
page 46)
Check lifting and lowering limiters
Daily
Replace buffer immediately if damaged, otherwise
(buffers) visually
replace every 5 years
Check EMERGENCY STOP function
Daily
Check chain
Every 3 months
(
Checking chain, chain sprocket and chain
guides section,
page 55) In the event of wear-
promoting operating conditions, reduce intervals
between checks
Checking lifting and lowering limiters
Annually
(
Checking lifting and lowering limiters,
section,
page 46)
Check brakes with load
Annually
Load must be braked reliably (
Checking braking
function
section, page 45)
Check all the bolted and-
Annually
pin connections
Check load hook on the load and
Annually
(
Check dimensions
section, page 55)
carrying side
Check the motor, check, clean and
Annually
Measure the lifting speed
rgrease the control valve
(JDN high-performance grease)
Check the axial movement of the hooks Annually
(
Checking axial play
section, page 57)
and eyes
Check the service unit
1
Annually
(
Service unit
section, page 47)
Check the silencer for permeability
Annually
(
Checking silencer for permeability
section,
page 46)
Check overload protection
Annually
(
Checking and adjusting overload protection
section, page 59)
Check compressed air connections
Annually
for damage
1