Control valve (on motor)
Note: In order to connect the hoses to the control
valve, we recommend removal of the hose adapter.
왘
Remove the hose adapter (secured via central bolt).
왘
Attach the hoses to the corresponding nipples (see
designation in illustration).
왘
Secure the hoses using the one-ear hose clamps and
crimping tool.
왘
Secure the strain-relief cable.
AT T E N T I O N !
The strain-relief rope must be installed with
the correct length in order to prevent loading
of the hoses.
왘
Pull the bellows over the hose adapter. The upper
collar of the bellows fits into the recess of the hose
adapter.
왘
In order to secure the hose adapter to the control
valve, a long A/F 6 socket spanner must be guided
between the three hoses, through the middle of
the bellows and inserted into the hexagon socket
of the bolt.
F - C O N T R O L C O N N E C T I O N
Pull the bellows over the hose bundle for F-control.
For F-control for lifting and lowering only, remove
approx. 80 mm of hose bundle protective sheathing;
for F-controls with additional functions (trolley/crane
movement) remove approx. 160 mm from end of
protective sheathing.
Pull the strain-relief ropes through the eye bolt and
secure them using rope clamps.
Insert the control hoses:
See illustration above
Compressed air
with hose designation 1 or colour: white
Movement direction ”lift”
hose designation 2 or colour: green
Movement direction ”lower”
hose designation 3 or colour: red
Bellows with A/F 6 socket spanner
Hose adapter with nipples designation lift, lower
powered by air !
I N I T I AL OP E R AT I O N
Page 24
Lower
Raise
Compressed air
connection
Dowel pin