NEW STRALIS MY2016
‒
GUIDELINES FOR BODYBUILDERS
ELECTRONIC SUB-SYSTEMS
5.2
BODYBUILDER CONNECTORS
23
–
Printed 692.68.697
–
5 Ed. - Base 03/2019
on the entire Bodybuilder interface functioning properly. The Bodybuilder is responsible for initiating measures to ensure that the "Safe
State" of the application activates independently.
●
If the application also requires a "recovery" strategy while the "Vehicle with full CAN operation" output is passive, contact IVECO.
●
The 'Vehicle StoppedState' signal values will be transmitted directly after the Bodybuilder Emergency has been activated and will re-
main active until:
■
K15 is switched off or
■
the CANopen NMT 'Start Node' command is received or
■
the CANopen NMT 'Start all Nodes' command is received
■
the CANopen NMT 'Start via HW input' is configured and the signal is reactivated.
Note:
During the 'StoppedState' phase, the relevant CANopen signals received on BB-CAN are ignored.
(3)
The stop brake can only be activated with vehicle speed below 6 km/h. On EBS vehicles a new Stopping Brake request is ser-
viced only when engine is running. When Stopping brake being active the engine could be stopped and Stopping brake remains
engaged.
The Stopping brake is only supported during K15 ON phase, switching off K15 disable the function on ABS vehicles. On vehicles
with EBS brake system the Bodybuilder automatically deactivates the stop brake request when K15 is switched off.
(4)
An input on the waste compactor footboard (occupied footboard) activates the following actions on the actuated footboard
switch, as described in Standard EN 1501-1 - Directives for occupied footboard:
●
speed limiting
●
reverse gear for rear loaded compactor. In the case of reverse gear engaged, protection by:
■
brakes activation;
■
torque limit set at 0% (only regulator at idle speed);
■
reverse gear is only prevented with automatic gearboxes if the input 72072A/03 is connected to ground by the Body-
builder.
(5)
The addition of a load on this output involves the addition of a diode, even if the output interacts with the Bodybuilder enable
control on 72072/03. Alternatively, the relay module R2 25781 can be removed on mechanical gearboxes (relay for EM - Neutral
25626 - see Figure 37).
(6)
It is possible to display information relating to the vehicle load on the Instrument Panel, but only for the comfort functions. To
enable this function, contact the IVECO Assistance Service. If wiring is added to the input(s), the relative CANopen objects regard-
ing vehicle load information are no longer available. On the Stralis EVO range the trailer load information via ISO11992-3 is not
supported on the Euro 6 range.
191315
Figure 17
(Pictures are by way of example only)
By using this function, alarm thresholds can be set for each type of load.
Содержание Stralis MY 2016
Страница 1: ...I S S U E 0 3 2 0 1 9...
Страница 3: ...Printed 692 68 697 5 Ed Base 03 2019 UPDATE DATA Section Chapter Description Revision date...
Страница 6: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 7: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 1 GENERAL INFORMATION...
Страница 8: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 10: ...4 NEW STRALIS MY2016 GUIDELINES FOR BODYBUILDERS GENERAL INFORMATION Printed 692 68 697 5 Ed Base 03 2019...
Страница 26: ...20 NEW STRALIS MY2016 GUIDELINES FOR BODYBUILDERS GENERAL INFORMATION Printed 692 68 697 5 Ed Base 03 2019...
Страница 27: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 2 CHASSIS INTERVENTIONS...
Страница 28: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 86: ...60 NEW STRALIS MY2016 GUIDELINES FOR BODYBUILDERS CHASSIS INTERVENTIONS Printed 692 68 697 5 Ed Base 03 2019...
Страница 87: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES...
Страница 88: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 139: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 4 POWER TAKE OFFS...
Страница 140: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 142: ...4 NEW STRALIS MY2016 GUIDELINES FOR BODYBUILDERS POWER TAKE OFFS Printed 692 68 697 5 Ed Base 03 2019...
Страница 165: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 5 ELECTRONIC SUB SYSTEMS...
Страница 166: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 168: ...4 NEW STRALIS MY2016 GUIDELINES FOR BODYBUILDERS ELECTRONIC SUB SYSTEMS Printed 692 68 697 5 Ed Base 03 2019...
Страница 225: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 6 ADBLUE AND SCRT SYSTEM...
Страница 226: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 228: ...4 NEW STRALIS MY2016 GUIDELINES FOR BODYBUILDERS ADBLUE AND SCRT SYSTEM Printed 692 68 697 5 Ed Base 03 2019...
Страница 235: ...Printed 692 68 697 5 Ed Base 03 2019 APPENDIX A STRALIS NP CURSOR CNG LNG...
Страница 236: ...Printed 692 68 697 5 Ed Base 03 2019...
Страница 238: ...4 NEW STRALIS MY2016 GUIDELINES FOR BODYBUILDERS STRALIS NP CURSOR CNG LNG Printed 692 68 697 5 Ed Base 03 2019...
Страница 254: ...Printed 692 68 697 5 Ed Base 03 2019...