Intel® Server Board SE7520BD2 Technical Product SpecificationPlatform Management Architecture
Revision 1.3
Intel Confidential
77
Sensor Name
Sen
s
or
#
Sensor
Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value/Offsets
Event Data
PEF
Action
SDR
Record
Type
Tach Fan 3
1Dh
Fan
04h
Threshold
01h
[u][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Tach Fan 4
1Eh
Fan
04h
Threshold
01h
[u][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Tach Fan 5
1Fh
Fan
04h
Threshold
01h
[u][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Tach Fan 6
20h
Fan
04h
Threshold
01h
[u][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Proc1 IERR
21h
Processor
07h
Sensor
Specific
6Fh
IERR As –
Trig
Offset
– 02
Proc2 IERR
22h
Processor
07h
Sensor
Specific
6Fh
IERR As –
Trig
Offset
– 02
Proc1 Thermal trip
23h
Processor
07h
Sensor
Specific
6Fh
Thermal Trip
As
–
Trig Offset
Fault LED
Action
02
Proc2 Thermal trip
24h
Processor
07h
Sensor
Specific
6Fh
Thermal Trip
As
–
Trig Offset
Fault LED
Action
02
Proc1 Thermal
Control
25h
Temp
01h
Threshold
01h
[u][ c,nc]
As & De
Analog
Trig Offset
Fault LED
Action
01
Proc2 Thermal
Control
26h
Temp
01h
Threshold
01h
[u][ c,nc]
As & De
Analog
Trig Offset
Fault LED
Action
01
Diagnostic Interrupt
Button
27h
Critical
Interrupt
13h
Sensor
Specific
6Fh
FP NMI Button As
–
Trig Offset
NMI Pulse 02
Chassis Identify
Button
28h
Button
14h
Generic
03h
State Assert
As
–
Trig Offset
ID LED
Action
02
Proc1 Fan
29h
Fan
04h
Threshold
01h
[u,l][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Proc2 Fan
2Ah
Fan
04h
Threshold
01h
[u,l][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Proc1 Core temp
2Bh
Temp
01h
Threshold
01h
[u,l][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Proc2 Core temp
2Ch
Temp
01h
Threshold
01h
[u,l][ c,nc]
As & De
Analog
R, T
Fault LED
Action
01
CPU Configuration
Error
2Dh
Processor
07h
Generic
03h
State Asserted As & De
Discrete
R, T
Fault LED
Action
02
OEM Type 53h
-
OEM Type
53h
N/A N/A
N/A N/A
N/A N/A
N/A