Intel® Server Board SE7520BD2 Technical Product SpecificationPlatform Management Architecture
Revision 1.3
Intel Confidential
75
•
Diagnostic Interrupt (Front Panel NMI) Handling
•
SMI/NMI status monitor (Standard and Advanced systems only)
•
System interface to the IPMB (via System Interface Ports) (Standard and Advanced
systems only)
•
System interface to the PCI SMBus (via System Interface Ports) (Standard and
Advanced systems only)
•
Secure Mode Control - front panel lock/unlock initiation.
•
IPMI v2.0 Management Controller Initialization Agent function (Standard and Advanced)
•
Emergency Management Port (EMP) Serial/Modem platform management interface
(Standard and Advanced systems only)
•
Dedicated Network Interface Controller (NIC) and full TCP/IP software stack (Advanced
only)
Table 40. mBMC Built-in Sensors
Sensor Name
S
e
ns
or
#
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value /
Offsets
EventData
Physical Security
Violation
01
Physical
Security 05h
Sensor
Specific
6Fh
LAN Leash Lost
As
LAN Leash
Lost
Trig Offset
Platform Security
Violation
02
Platform
Security
Violation
Attempt
06h
Sensor
Specific
6Fh
Out-of-band
access password
violation
As –
Trig
Offset
Power Unit Status
03
Power Unit
09h
Sensor
Specific
6Fh
Power On/Off
Power cycle
AC Lost
As –
Trig
Offset
Button 04h
Button
14h
Sensor
Specific
6Fh
Power Button
Reset Button
As –
Trig
Offset
Watchdog 05h
Watchdog2
23h
Sensor
Specific
6Fh
Timer Expired
Hard Reset
Power Down
Power cycle
Timer Interrupt
As
–
Trig Offset
System Boot
06h
System boot
Initiated
1Dh
Sensor
Specific
6Fh
Initiated by power
up
Initiated by hard
reset
Initiated by warm
reset
As
–
Trig Offset
System PEF Event 07h
System Event
12h
Sensor
Specific
6Fh
PEF Action
As
–