89
En
The 12V triggers A, B, and C can be used to turn on 12V
trigger-capable components automatically when they are
selected as the input source. The triggers can be set so that
they activate when a connected component is selected as
the input source for the main room, Zone 2, Zone 3, Zone
4, or any combination of rooms.
When triggered, the output from a
12V TRIGGER OUT
goes high (+12 volts and 150 milliamperes max. at
TRIG-
GER OUT A
; +12 volts and 25 milliamperes max. at
TRIGGER OUT B
and
C
).
When several components are turned on simultaneously
by using triggers A, B, and C, depending on the type of
components, a large amount of current may be drawn
momentarily. To prevent this, you can delay trigger signals
A, B, and C individually. Another application for trigger
delay is eliminating the “thump” noise that’s sometimes
heard when a source component is turned on.
Delaying the trigger signal for your power amplifier so
that it’s the last component to be turned on will accom-
plish this.
Using the 12V Triggers
Hookup
• Use a miniplug cable to connect the AV receiver’s
12V
TRIGGER OUT
A
,
B
, or
C
jack to the 12 V trigger
input on a connected component.
1
Press
Receiver
followed by
Setup
.
The main menu appears onscreen.
If the main menu doesn’t appear, make sure the
appropriate external input is selected on your TV.
2
Use
q
/
w
to select “Miscellaneous” and then press
Enter
.
The “
Miscellaneous
” menu appears.
3
Use
q
/
w
to select “12V Trigger A, B, or C Setup”
and then press
Enter
.
The “
12V Trigger A/B/C Setup
” screen appears.
4
Use
q
/
w
to select “Delay,” and use
e
/
r
to select
trigger signals.
`
0sec
(Trigger A: default),
1sec
(Trigger B: default),
2sec
(Trigger C: default),
or
3sec
.
When “
0sec
” is selected, the trigger signal is output
as soon as the input source is changed.
5
Use
q
/
w
to select an input source, and use
e
/
r
to
select an option.
`
Off
:
No trigger signal is output.
A 12-volt trigger signal is output when the connected
component is selected as the source for:
`
Main
(Trigger A: default):
Main room.
`
Zone 2
(Trigger C: default):
Zone 2.
`
Main/Zone 2
:
Main room or Zone 2.
`
Zone 3
:
Zone 3.
`
Main/Zone 3
:
Main room or Zone 3.
`
Zone 2/Zone 3
:
Zone 2 or Zone 3.
`
Main/Zone 2/Zone 3
:
Main room, Zone 2, or Zone 3.
`
Zone 4
:
Zone 4.
`
Main/Zone 4
:
Main room or Zone 4.
`
Zone 2/Zone 4
:
Zone 2 or Zone 4.
`
Main/Zone 2/Zone 4
:
Main room, Zone 2, or Zone 4.
`
Zone 3/Zone 4
:
Zone 3 or Zone 4.
`
Main/Zone 3/Zone 4
:
Main room, Zone 3, or Zone 4.
`
Zone 2/Zone 3/Zone 4
:
Zone 2, Zone 3 or Zone 4.
`
Main/Zone 2/Zone 3/Zone 4
(Trigger B:
default):
Main room, Zone 2, Zone 3, or Zone 4.
6
When you’ve finished, press
Setup
.
The setup menu closes.
6–3. 12V Trigger A Setup
Delay
BD/DVD
VCR/DVR
CBL/SAT
GAME
PC
AUX
0sec
Main
Main
Main
Main
Main
Main