56
En
Level Calibration
Here you can adjust the level of each speaker with the
built-in test tone so that the volume of each speaker is the
same at the listening position.
■
Left, Front Wide Left, Front High Left, Center
*1
,
Front High Right, Front Wide Right, Right,
Surround Right, Surround Back Right,
Surround Back Left, Surround Left
`
–12.0dB
to
0.0dB
to
+12.0dB
in 0.5 dB step.
■
Subwoofer 1
*1
, Subwoofer 2
*1*2
`
–15.0dB
to
0.0dB
to
+12.0dB
in 0.5 dB step.
Note
• Speakers that you set to “
No
” or “
None
” in the
“
Speaker Configuration
” cannot be selected (
➔
54
).
• The speakers cannot be calibrated while the AV receiver is
muted.
• The test tone is output at the standard level for THX, which is
0 dB (absolute volume setting 82). If you normally listen at vol-
ume settings below this, be careful because the test tone will be
much louder.
• The “
Level Calibration
” setting cannot be selected if “
Audio
TV Out
” setting is set to “
On
”.
*1
For the center speaker and subwoofer, the level settings made
by using the Home menu are saved (
➔
27
).
*2
If the “
Subwoofer
” setting is set to “
1ch
”, this setting cannot
be selected (
➔
54
).
Tip
• If you’re using a handheld sound level meter, adjust the level of
each speaker so that it reads 75 dB SPL at the listening position,
measured with C-weighting and slow reading.
Equalizer Settings
With the Equalizer settings, you can adjust the tone of
speakers individually with a 15-band equalizer. The vol-
ume of each speaker can be set (
➔
56
).
■
Equalizer
`
Manual
:
You can adjust the equalizer for each speaker manu-
ally. If you selected “
Manual
”, continue with this
procedure.
`
Audyssey
:
This is selected automatically by
Audyssey MultEQ XT32 Room Correction and
Speaker Setup function. The
Audyssey
indicator will
light (
➔
9
) and “
Dynamic EQ
” and
“
Dynamic Volume
” become available (
➔
60
).
When “
Audyssey
” is selected, “
Dolby Volume
”
becomes “
Off
” automatically (
➔
58
).
`
Off
:
Tone off, response flat.
This setting is set automatically by
Audyssey MultEQ
®
XT32 Room Correction and
Speaker Setup function (
➔
29
).
This setting is set automatically by
Audyssey MultEQ XT32 Room Correction and Speaker
Setup function (
➔
29
).
1
Press
w
to select “Channel”, and then use
e
/
r
to select a speaker.
2
Use
q
/
w
to select a frequency, and then use
the
e
/
r
to adjust the level at that frequency.
The volume at each frequency can be adjusted
from
–6dB
to
0dB
to
+6dB
in 1 dB steps.
Note
• You can select: “
25Hz
”, “
40Hz
”, “
63Hz
”,
“
100Hz
”, “
160Hz
”, “
250Hz
”, “
400Hz
”, “
630Hz
”,
“
1000Hz
”, “
1600Hz
”, “
2500Hz
”, “
4000Hz
”,
“
6300Hz
”, “
10000Hz
”, or “
16000Hz
”. And for the
subwoofer, “
25Hz
”, “
40Hz
”, “
63Hz
”, “
100Hz
”, or
“
160Hz
”.
• While the Direct listening mode is selected, the
equalizer settings have no effect.
Tip
• Low frequencies (e.g., 63Hz) affect bass sounds;
high frequencies (e.g., 16000Hz) affect treble
sounds.
3
Use
q
to select “Channel”, and then use
e
/
r
to select another speaker.
Repeat steps 1 and 2 for each speaker.
You cannot select speakers that you set to “
No
”
or “
None
” in the “
Speaker Configuration
”
(
➔
54
).
Содержание DTR-70.2
Страница 1: ...AV Receiver DTR 80 2 DTR 70 2 Instruction Manual ...
Страница 122: ...122 En Memo ...
Страница 123: ...123 En Memo ...