Chapter 5:
Console Operation
Monitoring
192/ 380
V1.0/1
Eclipse User Guide
Automatic Monitor Switching
This feature allows you to configure automatic monitor
switching in response to different channel
CUE
s. For example,
if some musicians use wedge monitors while others use in-ears,
you can setup your monitor switching to respond to the different
channel
CUE
s.
Let’s take an example of configuring automatic monitor
switching on monitor outputs 1 and 2:
1.
Press and hold the
01
button on the TB/MONITORING
panel while you press the
CUE
buttons on the channels
you wish to assign to this monitor circuit:
2.
Now press and hold the
02
button, and press the
CUE
s
you wish to assign to monitor circuit 2:
3.
You can check which channels are assigned to each
circuit at any time by pressing the
01
or
02
buttons.
All CUEs assigned to the selected circuit become active.
4.
To remove a channel, press and hold the
01
or
02
button and deselect the
CUE
.
Having configured the two monitor circuits:
5.
Press a
CUE
button on faders 13 to 16 and monitor
circuit
01
is automatically selected.
6.
Press a
CUE
button on faders 19 to 24 and monitor
circuit
02
is automatically selected.
You can configure this operation for up to three monitor circuits.