Chapter 5:
Console Operation
Smart Busses
(SBus):
Smart
Bus Tips
168/ 380
V1.0/1
Eclipse User Guide
Smart Bus Tips
When Smart Busses are configured, they default so that the
Smart Bus component channels (XBus) are closed and
MUTE
is active.
You can change this by setting a
General Preferences
option
so that when a Smart Bus is patched its level is automatically
set to 0dB, see Page 341.
Regardless of this level preference, it is worth checking all of
the following:
1.
Press
SEL
on the first Smart Bus VCA and set its fader
level to 0dB with
MUTE
off.
2.
Press and hold the
SEL
button on the Smart Bus VCA
and press
SEL
buttons on all the inputs you wish to route
from.
You should also configure any pre-fader or Independent sends
at this time. See Page 142 for details.
3.
Now adjust the Left, Centre, Right and Mono Smart Bus
component channels to the levels you require and deselect
any slave
MUTE
buttons.
4.
Pan each slave and adjust its initial EQ, Dynamics, etc.
5.
Now repeat these steps for each Smart Bus on the
console.
This will provide a good starting point for your mix.