P108 [Speed Reference]
Related Parameter(s): d001, d002, d012, P109, P110, t201, t202, A409, A410-A413, t211, t212, t213,
t214
Sets the source of the speed reference to the drive.
The drive speed command can be obtained from a number of different sources. The source is
normally determined by P108 [Speed Reference].
However, when t201 - t202 [Digital Inx Sel] is set to option 2, 4, 5, 6, 11, 12, 13, 14 and the digital
input is active, the speed reference commanded by P108 [Speed Reference] will be overridden.
Refer to the flowchart in chapter 1 for more information on speed reference control priority.
Options 0
“Drive Pot”
(Default)
Internal frequency command from the potentiometer on the
integral keypad.
1
“Internal Freq”
Internal frequency command from A409 [Internal Freq].
2
“0 – 10V input”
External frequency command from the 0-10V analog input or
remote potentiometer.
3
“4 – 20 mA input”
External frequency command from the 4-20mA analog input.
4
“Preset Frequency”
External frequency command as defined by A410 - A413 [Preset
Freq x] when t201 and t202 [Digital Inx Sel] are programmed as
“Preset Frequencies” and the digital inputs are active.
5
“Comm port”
External frequency command from the communications port.
P109 [Accel time 1]
Related Parameter(s): P108, P110, t201, t202, A401, A410 - A413
Sets the rate of acceleration for all speed increases.
Values
Default:
10.0 Secs
Min/Max:
0.0/600.0 Secs
Display:
0.1 Secs
Содержание ILVFE-1W0075
Страница 1: ......
Страница 2: ...2 ILVFE series user manual...
Страница 23: ...ILVFE series user manual 23...
Страница 74: ...74 ILVFE series user manual Product dimensions Frame A Frame B Frame C...
Страница 75: ...ILVFE series user manual 75 Recommended external brake resistor circuitry External display optional...
Страница 79: ...ILVFE series user manual 79 Additional information More info can be found on our website www indulogix com...
Страница 80: ...80 ILVFE series user manual...
Страница 81: ......