42
ILVFE-series
user manual
P110 [Decel time 1]
Related Parameter(s): P108, P109, t201, t202, A402, A410 - A413
Sets the rate of acceleration for all speed increases.
Values
Default:
10.0 Secs
Min/Max:
0.1/600.0 Secs
Display:
0.1 Secs
P111 [Motor OL ret]
Related Parameter(s): P103
Enables/disables the Motor Overload Retention function. When Enabled, the value held in the motor
overload counter is saved at power-down and restored at power-up. A change to this parameter
setting resets the counter.
Options
0
"Disabled" (Default)
1
"Enabled"
P112 [Reset to defaults]
Related Parameter(s): d012, P107
Resets all parameter values to factory defaults
Options
0
"Idle state" (Default)
1
"Reset defaults"
After the reset function is complete, this parameter will set itself back to "0". Causes an F48 Params
defaulted fault.
Stop drive before changing this parameter