CAMERAS FRAME GRABBERS IMAGING SOLUTIONS
BOBCAT Hardware User’s Manual
IMPERX
Rev. 2.0.7
6421 Congress Ave.
4/8/2014
Boca Raton, FL 33487
www.imperx.com
+1 (561) 989-0006
250 of 329
PAOI Horizontal Width
Address
:
0x0244
Data (11:0)
:
<value> PAOI width in horizontal direction
Data (31:12)
:
N/A
PAOI Vertical Offset
Address
:
0x02A4
Data (11:0)
:
<value> PAOI offset in vertical direction
Data (31:12)
:
N/A
PAOI Vertical Height
Address
:
0x0284
Data (11:0)
:
<value> PAOI height in vertical direction
Data (31:12)
:
N/A
4.5 LENS CONTROLLER REGISTER DESCRIPTION
4.5.1 Lens Controller Workspace Registers
4.5.1.1 Pulse Width Selection
This register sets the lens controller motor drive pulse width.
Address
: 0x042C
Data (3:0)
: 0x0 – 1 ms
: 0x1 – 2 ms
: 0x2 – 4 ms
: 0x3 – 8 ms
Data (31:8)
: N/A
4.5.1.2
Voltage
This register sets the lens controller control voltage.
Address
: 0x042C
Data (7:4)
: 0x0 – 6 volts
: 0x1 – 12 volts
Data (31:8)
: N/A
4.5.1.3
Zoom Travel Distance Selection
This register sets the number of motor control pulses to control zoom travel distance.
Address
: 0x0424