CAMERAS FRAME GRABBERS IMAGING SOLUTIONS
BOBCAT Hardware User’s Manual
IMPERX
Rev. 2.0.7
6421 Congress Ave.
4/8/2014
Boca Raton, FL 33487
www.imperx.com
+1 (561) 989-0006
214 of 329
4.3.2.2
Load From Factory
The
‘Load From Factory’
command instructs the camera to load its workspace from
the factory space. All current workspace settings will be replaced with the contents of
the factory space. This is a command, not a register. The act of writing to this location
initiates the load from the factory.
Address
:
0x6060
4.3.2.3
Load From User #1
The
‘Load From User #1’
command instructs the camera to load its workspace from
the user #1 space. All current workspace settings will be replaced with the contents of
the user #1 space. This is a command, not a register. The act of writing to this location
initiates the load from the user #1.
Address
:
0x6064
4.3.2.4
Load From User #2
The
‘Load From User #2’
command instructs the camera to load its workspace from
the user #2 space. All current workspace settings will be replaced with the contents of
the user #2 space. This is a command, not a register. The act of writing to this location
initiates the load from the user #2.
Address
:
0x6068
4.3.2.5
Load MFG Default Gain
The
‘Load MFG Default Gain’
command instructs the camera to load its default
gain and offset settings from the manufacturing space. Different settings will be loaded
for “slow” and “fast” camera speed. This is a command, not a register. The act of
writing to this location initiates the load the default gain and offset settings.
Address
:
0x606C
4.3.2.6
Save to User #1
The
‘Save To User #1’
command instructs the camera to save its workspace to the
user #1 space. All current workspace settings will be saved to the user #1 space. This
is a command, not a register. The act of writing to this location initiates the save to
user #1 space.
Address
:
0x6074