7.
Odd/Even Frame Flag – a signal indicating if the frame is ODD or
EVEN. It alternates every frame. When “Active High” ODD is
LOW.
8.
Trigger Pulse – maps the input trigger pulse to the output with no
delay (as is).
9.
Trigger Pulse Delayed – maps the input trigger pulse to the output
with delay set by the Exposure Delay Register.
10.
Camera Ready – a signal indicating when the camera is ready to
accept the next trigger pulse.
11.
Pulse Generator – maps the internal pulse generator waveform to the
output.
12.
Strobe 1 – maps “Strobe One” signal to the corresponding external
output.
13.
Strobe 2 – maps “Strobe Two” signal to the corresponding external
output.
14.
Deselect – no signal is mapped.
5.7.3 Trigger
Trigger window is used to set the camera trigger modes and trigger settings – Figure 5.12.
Four control panels are associated with this feature: “Settings”, “Acquisition Control”,
“Exposure control” and “Strobe Control”.
Figure 5.12 – Trigger parameter window
Settings
:
Trigger in
– selects the active triggering input signal. The selected
trigger signal must be mapped to the corresponding camera input.
1.
Off – the camera is in free-running mode.
2.
External – the camera expects a trigger signal coming from IN1 or
IN2 inputs.
3.
Pulse Gen – the camera expects a trigger signal coming from the
internal pulse generator.